Answer / rathish
In any DC motor the speed depends inversely on the flux.
Consider when starting a series motor the current flowing
will be high, but the flux that the motor produces will be
moderate since the series winding has less number of turns.
If u start the motor without load the speed will increase.
as speed increases the back emf increases. this decreases
the current through the series winding and hence flux
decreases and the speed further increases. Theorerically
speaking the speed becomes infinite. But practically the
motor will accelerate to very high speed , which will damage
the motor. But if you start the motor with the load, you are
actually reducing the starting speed hence the motor runs
safely. Since series motors has this property it is used in
trains to pull high load.
shunt motor starting torque is
marginal and hence it should be started with least load.
Is This Answer Correct ? | 0 Yes | 0 No |
RRB GROUP D GANGMEN RESULT 2012
The particles which conduct electricity in a solution of electrolyte are called (a) Electrons (b) Protons (c) Ions (d) Deutrons
Rrb result group r delhi
I am studying final year mechanical engineering. what is the procedure for me to get enter into engineering stream in RRB?
Asst Locopilot
What is the net salary of ldc in central government in delhi
can u send to me logo pilot questions?
do u want rrb previous questions with answers?
I am preparing RRB-Ajmer Enquiry cum Clerk & Goods Guard Exam. Previous or Model Exam papers please send my e-mail id: manzilrm@gmail.com
I have applied for Jr stenographer grade in April 2009
all railway recruitment board goods guard, assistant station master,commercial clerk and other non technical questions.
29 Answers RLY, RRB,
The unit of inductance is (a) Ohm (b) Farad (c) Henry (d) Coloumb