Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Civil Engineering Interview Questions
Questions Answers Views Company eMail

Project at andheri west mumbai total area of 116000 sq ft near by..Please help me out for quotation plan is ready basic details are with me , please help me out .I will mail u in autocad also.

AK Construction,

1 2578

explain five benefits of using standard terminology in the measurement process?

2247

How to convert 20 dia bar to 16 dia bar in beam without reducing the steel weight

L&T,

2016

while doing the structural works of a simple ground+1 villa, can the columns be continued immediately after neck columns without tie beam, while the tie beam to be done after columns concreting.

XYZ,

1700

for basic costing, how can we calculate how much amount of steel and cocrete will go in per sqft? and what are the thumbrules?

Symphony,

1 2899

Sunk slab means what ?

1 3339

hi guys what happens if you are absent for a supplymentry exam?

1886

how to calculate of m20 c.c road work 1cu.m

2044

Gidc technical que paper

GIDC,

1816

Stringer How many cm goes to landind

ACC,

1860

Rate analysis for construction of a solid block masonary of size 400x200x200 in C.M.1:5 in superstructure .Compressive strength 5.00 N/Sq.mm Confirming to IS: 12894:1990, with necessary scaffolding, raking of joints and pointing the same. I require rate per Cum.

Alagar Builders,

2597

Two way slab, curtailment provided in both side in longside and short side. which side curtailment provided in one way slab?

IBA,

1 3374

why steel tanks are provided (a) for water pressure (b) for wind pressure (c) for earthquake pressure

C&W,

1685

How many solid blocks can build one mason per 8 hours?

1 2930

How many bags of cement will be required for 45.5 M^3 Concrete with the ratio of 1 Cement+1 Crash+ 2 Sand+1 Gravel?

First MicroFinance Bank FMFB,

1837


Post New Civil Engineering Questions

Un-Answered Questions { Civil Engineering }

how to estimate costing from quantity givin in BOQ and according to this how we fill tender and final rate for perticular work.....?

2130


How to identify the vitrified tile and ceramic tile by observation only after executing the job.

1052


Types of column foundation and how to calculate its steel quantity.

2020


how beam.coloum ,slab, footing are designed as per indian code.. detail procedure?

2664


Define What are the reasons for geotechnical site investigations in Uganda?

1222


What are the joints wants to made in masonry where door opening, arches like etc..

1798


What is an object snap mode?

1243


5. Two long boundary walls run parallel to each other at a center to center distance of 1 meter apart. The width and height of the first wall are 0.30 m and 2.5m respectively. While those of the second are respectively 0.18m and 3.5m. Plot the distribution of vertical stress intensity due to walls on a horizontal plane, 1m below ground level. The walls have negligible depth of foundation and are made of brick masonry (y = 19.2 kN/m cu)

2197


what is the hanekom repairing material after concreting work

2475


what is the construction cost for per cft of multistorryed building in kolkata?

2317


Before casting a basement roof slab which is connected with retaining wall surcharge load (i.e. sand or earth filling) outside the retaining wall is prohibited because of––

2471


Form where IS456 is adopted in 1978?

2055


What is Grid floor and mention its advantages ?

3307


indian standard split spoon sampler

2020


how much quantity of 1.5" nails and 2.5" nails are required for conventional formwork shuttering?

1724