Instrumentation Interview Questions
Questions Answers Views Company eMail

wt is cold junction compensation

1 3785

how to convert bar to mA?

1 5800

What is inside the PLC panel? How does instruments communicate to DCS computer via PLC? What is the type of wiring in PLC connections? Please answer... Thanks

1 6766

all types of liquid analyzer principle with drawing?

1525

what is cems analyzer explain with principle and drawing ?

1864

how to work gas chromatography explain principle ?

2 3696

why we are using analytical instrument in plant ?

1 3617

what is wave length were using ?

1470

how to measure oxygen which methods are using?

1474

which types of oxygen analyzer describe with drawing ?

2 3760

what is ZERO SUPPRESION and ZERO ELEVATION?

Reliance,

3 9323

I have 475 hart communicator. this is not support any new type of instruments such as tranmitter,fieldvue DVC6200.DVC 200 since i got point out need to upgrade . my questions is how can upgrade new instruments software in my 475 hart communicator. can any answerplease>?

1 4891

Pls can anybody tell me how much memory plc's has?in byte or in Kb

2 3996

Can Any body tell me about the Contact or Email id of any good Consultancy which help me to find a job in Instrumentation Field in India .I have Six years of Work Experience in the Same field.Please revert me back on shammi_gwalior@yahoo.com ?

1442

what is shutoff dp? why is it important for selection of a control valve?

1 20167


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

what about your moleg in pogrees with company

1798


what is the minimum power (P=VI)to produce a spark?

1550


Linear amplifier.

1538


How to Calibrate Ultrasonic flow Transmitter in Field

787


please send me some question papers of HPCL aptitude test ?? please send it to bipinb.28@gmail.com ...

1507






What is the meaning of wet leg

669


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1439


how to turbine speed measurement?

1157


i need some objective type questions in instrumentation

4470


How to check vortex flow meter is in good condition while we do not having calibration setup?

7490


what is the diffrence between pressure safety valve & pressure relief valve....pls

1720


steps for installing orifice plate?

1350


What are the application of bernoulli’s theorem?

674


what is difference between fork type and capacitance type level switch. where it is using

1921


How to regulate the flow of Air in 4" line, with max flow of 330 nm3/hr and Pressure of 0.5 bar? please suggest the type of instrument required.