Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

Reliance Interview Questions
Questions Answers Views Company eMail

I May I know about your self you

2 4309

What is the unit standard weight,thicknessof C.I>Pipe of various Dia upto200 MM(as per IS1538)

2026

What IS PHP?

3 4907

What are the different types of earthing used in telecom sites ?

9 34605

why you like to join in FMCG sector?

8 50531

How the sizing of the analog signal cable is calculate?

1974

How will u plan a grounding network for a nw plant....

1431

We use PSWA card in which case?

1 2823

How many types of Transmission cards are in Ultra BTS?

10 37018

How can I only see the last 5 lines of a file?

10 10360

What is the full form and the application of SAP?

67 86045

i want interview questions about PROCESS CONTROL INSTRUMENTATION , SENSORS AND TRANSDUCERS IF ANY BADY KNOW ABOUT THAT PLEASE SEND TO MY MAIL karumudi1003@gmail.com

8 23097

vo kya cheez hai jo saal me ek bar, mahine me do bar,haphte me 4 bar or din me 6 bar aati hai..

7 90504

An electronic p controller has an input range of 1-5v, and output range of 4-20mA, while testing a step change of 0.4 was applied at the input , the PB setting was 50% ,what should be the change in the output ?

1 4813

what is an ambient temperature?

5 9810

Post New Reliance Interview Questions


Reliance Interview Questions


Un-Answered Questions

What is gson and json?

1


How often do you read the paper or watch the news on TV? How important is it for you to keep up with current events?

2963


What is dependency injection in swift?

468


Explain attributes of a component interface (ci) are?

477


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1440






what material is the electrical housing wire made of? is there any difference for the telephone lines?

1462


Will the amount of G418 be affected by serum concentration?

1350


How to convert objective c project to swift?

1


two phases with neutral supply can be taken in 3C X 10 sq.mm cable .

996


Explain what is jaxm messaging models?

335


what is sub-query? : Transact sql

589


What are edge triggered flip flop and level triggered flip flop?

559


How large is it preferred to configure the data volumes of a sap maxdb database?

1


2. Create your own definition of a system. Based on the “system” definitions a. Identify your viewpoint of shortcomings in the definitions. b. Provide rationale as to why you believe that your definition overcomes those shortcomings. c. From an historical perspective, identify three precedented systems that were replaced by unprecedented systems.

2714


Explain about routing and why do we use it?

407