Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

KPTCL Interview Questions
Questions Answers Views Company eMail

The first telegraph line between Calcutta and Agra was opened in (a) 1852 (b) 1853 (c) 1854 (d) 1855

4 24703

What is Ohms law?

28 35448

check list of maintenance of transformer?

11 113309

HOW DOES ONE SELECT A TRANSFORMER PHASOR GROUP IE, WHETHER A STAR-DELTA TR OR A STAR-STAR OR A DELTA-DELTA, ETC. TRANSFORMER IS MORE SUITABLE FOR A PARTICULAR KIND OF LOAD OR WORKING CONDITION???

3 7805

how to check the earth resistance value& what is the minimum earth resistance for good earthing sysytem.

33 154788

define frequency ?

14 21329

what will hapen if secodery circuit is open of current transformer

8 18548

how can we find a burden of potential transformer? what does it effects? how can we calculate rated load of it?

4 34646

in 400 kv system why should trip both side CB when we give hand trip?

1 7555

how to caluclate tds from emloyees and others

2118

Insulater disk using formula for 33/66/135 line h t line

1 5017

what is broken conductor indication

3 5146

We have 11kV/110V three phase indoor potential transformer in 66/11kV Sub-station, where the failure of PT is frequently happening and the rating of the PT is 0.2 class accuracy, with primary star and seconday (two cores) star connected. Some experts has suggested to not to connect the PT Primary neutral to the ground because when transformer neutal NCT connection is loose; the faulty current will flow through the PT primary neutral, resulting into failure of PT. My question is: Is it necessary to remove the primary neutral connection of the PT from ground? if not, what would be the reason for failure of PT. Please guide me.

2 3753

In my power station 220 volts dc battery set. they coneected 84th cell taped

1 2230

Post New KPTCL Interview Questions




Un-Answered Questions

How would you work with numbers other than those in the decimal number system?

856


composition of brass

1881


What is the heap?

1221


What is the function of grid naming service used in oracle rac

1


What is the two-dimensional array?

1019


from hplc chromatogram how can we say that calibration is needed now?

2545


what are six validation types?

1179


Enlist the various Media types used?

663


What is Simple Element?

933


What is lazy loading and eager loading?

464


Explain xctest test case code.

813


Define Bill of Exchange

1978


Can constructor be protected in c#?

947


What is overdraft?

1073


"Tell me about a job that you found particularly satisfying. What did you like about it?

3170