why the voltage is in digit of 11/33/132/220/440 please send me on shukrerabbi_abkhalil@rediffmail.com with thanks

3 Electrical Engineering 4522

In all analog voltmeters or ammeter showing some small size symbols. as well as a star and in star 2no. digit, resister symbol,and other. what is that's meaning ?

Electrical Engineering 1575

In all analog voltmeters or ammeter showing some small size symbols. as well as a star and in star 2no. digit, resister symbol,and other. what is that's meaning ?

1 Electrical Engineering 14260

what is accuracy ? in any meters , coils accuracy . how can u defined that ?

Adani,

Electrical Engineering 1915




Answers / { ab. khalil khan }

Question { Lanco, 93377 }

what is DG synchronization panel
plz explain the working!!!!!!!


Answer

D.G. synchronizing panel have working with grid synchronizing also. If suddenly grid line failed at that time u have operate
your D.G. set but after grid line coming have u change over in D.G. to grid. for that change over u can set your frequency , voltage equal to grid line frequency , voltage and closed the breaker . after synchronized stop your generator .
for detail or if u have any suggest me then cont. to me on my no. 9977278622 (Ab. Khalil Khan)
with best regards.

Is This Answer Correct ?    16 Yes 11 No

Question { 5334 }

We have a 33/11kv switchyard having 12.5 MVA power
transformer. We export & import power through this
transformer. When we export power, the PF will be depend on
GRID PF & when we import power the PF will be depend on our
load PF. but the problem is that,when neither we export nor
import but our 33KV vCB is in close position,our meter read
the power factor 0.14 to 0.25 at that moment. So how can be
we improve the power factor at that moment.


Answer

are load variation in your plant? If variation for some minutes are in your plant then this problem should be created. In load time power factor was normal but on no load time power factor was abnormal, because we have maintain the power factor in on load position.At no load time capacitive power has make a leading power factor.for detail pl. cont. to Ab. Khalil 9977278622

Is This Answer Correct ?    1 Yes 0 No


Question { Reddy Labs, 3109 }

how does it help for selection of a transformer.


Answer

1) How is your load.
2) load are veriable or holded.
3) want u transformer out door or indoor.
4) how many rediator u want in your transformer.
5) if u want other detail about that then pl. cont. me on
my no.9977278622 (khalil khan)

Is This Answer Correct ?    0 Yes 0 No