what do you mean by MACO
Answers were Sorted based on User's Feedback
Answer / lava khandelwal
MACO = Maximum Allowable Carryover (MACO), its limit could
be establish as below:
TDDprevious x MBS
MACO = ------------------------------
SF x TDDnext
MACO Maximum Allowable Carryover: acceptable transferred
amount from
the investigated product ("previous")
Thanks
Lava Khandelwal
08650002470
| Is This Answer Correct ? | 8 Yes | 0 No |
Maximum Allowable Carryover (MACO)is the limit of previous product in next product during cleaning validation.
can be calculated by the formula-
TD x BS xSF
MACO = ----------------
LDD
where,
TD: single therapeutic dose of product A
BS : bach size of product B(minimum batch size)
SF: safety factor(1/1000) or 0.001
LDD : largest daily dose of product B
| Is This Answer Correct ? | 4 Yes | 0 No |
what are all the parameters to be considered while applying bracketing and matrixing?where and all it is applicable?
Why we are disodium tartare for factor of karlficher titration ?
What should be the LOD of dry syrup?
hai,i had completed my b.pharmacy.i want the coaching centres for drug inspector exam at hyderabad,pls help me nd wen wil b the DI exam conducted in 2012 mostly,pls also forward the model papers.. pls reply me at pravaliden@gmail.com
i have completed b. pharmacy .i want model papers for drug inspector examination
what is manual integration in HPLC
3 Answers Hetero, Jubilant, Lupin,
why doctor prescribe antibiotics for viral infection instead of antiviral drugs?
What is the acceptance criterion for detergent washing?
Hai,i had completed my M.pharmacy.i want the coaching centres for drug inspector exam at hyderabad,pls help me nd wen wil b the DI exam conducted in 2012 mostly,pls also forward the model papers.. pls reply me at vislawath.jyothi@gmail.com
Why we are using propyl parabben in methanol in calibration of hplc for GPV test??
what are the limit of LOD and LOQ
principle of dissolution
0 Answers Combitic Global Caplet,