why dc series motors never start without some load, and what will happen if starting with out load..
1 4173EXPLAIN WHY THE SURGE CURRENT RATING OF AN MCCB OR CIRCUIT BREAKER DECREASES WITH INCREASE IN THE RATING OF MCCB OR CIRCUIT BREAKER.
2034if 12v battery get discharged for 2 months after if we put charge it will charge again?how much time it will take to charge?
1940what happens to a turbo alternator if it get trip and 1 out of 3 poles of circuit breaker in close condition
1 4570Hello friends., my question is related to testing of current transformer... A Ct having knee point voltage of 750 volts., and I have two step up transformer's of rating 230 v to 440 volts., can I obtain the value of 750 volts by using the two transformer's.... If yes then how could I connect the transformer's to obtain knee point voltage?? thank you in advance
ABB,
1 4712why are the likely reasons for bochholz & pressure relays oprate due to a internal fault but not differential relay ?
2 4671Post New Electrical Engineering Questions
If we have to feed a housing complex having load 8MVA, than what would be the better option, either we first step down 33kv supply into 11kv & than 430v or we proposed no of 33/.44 kv transformer, also which option is economical?
How can we calculate the KVA rating of a Distribution transformer from its core details?
What happens if i apply 500V to 440V rotary Switch ?
What is the working principle of servo motor? And explain it.
How to calculate Voltage regulation of 22 KV Over head Line.
does the Trivector Meter of three phase automatically takes care of the low power factor and gives the reading accordigly or it does not take care of the Power factor while giving the readings please explain
what will happen if there is a voltage leakage or current leakage in an electrical train
Is better to supply the voltage for static exciter from the auxiliary power source or from the SG terminals? And why?
why HT armoured cable does not glanding
I want formula to calculate cable size as per load given in length & amp. I searched many sites but didn't right answer. Please reply me asap.
1) Explain why we don't link the two earthing system ht and mv on a pole mounted transformer sub-station.
can i use 2000/5A Clamp meter to measure HT cable
where reactive power is used
Why HT 11 KV Slipring Motors are connected in star ?
what are the advantages disadvantages of connecting high voltage block( 1:1 transformers) transformers between the turbo generators and busbars.