Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

why we are using pnp npn for sensors is there any other type?

CGL,

1 2519

why we are using boosters at glass furnace is there any other thing?

CGL,

1 2278

admittance level sensor meaning?

CGL,

2 4276

How comparison of objects is done in PHP5?

TIS,

1 2765

Why MUX JB's are using only Temperature Element in Fundation field bus?

Reliance Industries,

2339

why we use 3 wire rtd direct wiring for temperature measurement instead of temperature transmitter like bearing temperature

ABG Energy,

1830

What is the difference between precision and repeatability of any instrument. Why it is measured always in percentage

2 3673

How do understand by hart protocol?

BW Instrumentation Electrical,

4 4761

Yokogawa dcs nodes advantages?

Petrochemicals,

1921

Yokogawa dcs normally where will change 4-20 MA to DC voltage( node or I/o cards?)

1 3357

Boiler flame scanner advantage?

Fluke, Petrochemicals, Tata Chemicals,

1827

give classification of transducer based on type of application

2 3471

How do you calibration D.P transmitter? ?

Power Plant,

2 4140

In which principles tx ,pressure gauge,Temp gauge,control valve works?

Bajaj, Professional Instruments,

1822

How to work temperature gauge?

KJS,

1880


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

how to calibrate mass flow meter (Coriolis)? Example calibration range: 0 to 2500 kg/hr line size 3" fluid: Etheline glycol (MEG)

2686


What is exact difference between the panel earthing and system earthing in DCS system. What is the value of resistence.

2674


what are the different types of Protocols? & their applications.

30699


Instrument QA/Qc what is the project quality plan?conduit inspection RFI. which documents attache with package?

10857


what is the procedure of belt scale calibration?

2445


how works encoder in plc

2088


How to decrease opening & closing time of on/off valve?

1516


1.what is controller proportional gain 2.what is the controller intergral action time. 3.A proportional plus derivative controller that has a proportional band of 20% and a derivative action time of 0.1 minutes. Construct the shape of the output waveform for the triangular input if the input rises and falls at the rate of 4 units per minute.

2689


what is dc moter.

2236


How is flow measured in square root?

1299


can any one explain in which term we are flow flow is it volumetric r is it mass? and y

1944


what is the calibration procedure for transweigh make weigh feeder?

4029


Explain the working of an electronic level troll.

1100


What are the uses of orifice plates?

1087


how to do dynolab wind speed sensor loop test, how to simulate value,i have simulate mA 4-20mA but not responding in DCS faceplate, please kindly advice me any one.