Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

OPS Interview Questions
Questions Answers Views Company eMail

why in three phase 440 circuit in all phase current is almost equal L1-35 A,L2-34 A ,L3-31 A but in nutral when i check with clamp meter it shows 25 A?

4 13280

why for transformer protection we protect tranformer from 3rd hormonics and 5th hormonics and what is the reason of generating these horminics in electrical system?

2 9755

what is difference between start imitation and start interlock for 3 phase motor protection ?

2 7940

how we can adjust for three phase motor cold stall time ,hot stall time and thermal register set up?

2897

why voltage rating not mention at HPSV or HPMV lamps?

2 6808

can we use HPSV LAMP in HPMV LAMP fixture ?and viseversa.

5 13761

Why Transformer Neutral having one earth pit ( more earth electrode resistance) whereas body have many earth pit ( less earth electrode resistance)?

4342

how to calculate restraing current and operating current for differential protection if 20 mva transformer is OLTC 33 kv/11 kv ? and what should be the type and ratio of CT?

2 6062

how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage.

1 4749

how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2227

Post New OPS Interview Questions




Un-Answered Questions

distribution is maximum done by a)radial b)network c) parallel d)b & c

1960


Explain the difference between int and int32?

951


How do I use microsoft word 2007?

560


How do I fix windows failed to load because a critical system driver is missing or corrupt?

831


Describe data concatenation?

1090


How would you screen for outliers and what should you do if you find one?

111


What is the ipconfig command for linux?

1037


What are the fields in the memory table ‘screen’?

1065


What are the functional areas? User groups?

1150


What will cause the size of a stored procedure to grow in sybase?

824


How do I anchor a textbox in word?

626


What are the difference between idattribute and attributes?

5


What is the link between the Balance Sheet and the Statement of Cash Flows?

1217


What is pom xml?

829


ii) A shunt motor supplied at 230V, runs at 900 rpm when the current is 30A. The resistance of the armature is 0.4 ohms. Calculate the resistance required in series with the armature to reduce the speed to 600 rpm, assuming that the armature current is then 20A. [12]

2392