Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

whate is difference between calibration and validation

Answer Posted / thiruathi swamy

Validation mean documented evidence that a particular
instrument or process produce results meet predetermined
specification.
Calibration means particular instrument or device produce
results by comparison of known reference standard.

Is This Answer Correct ?    39 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why we used in n-butyl acetate water content terminology while in ethyl acetate we used moisture content terminology?

1904


How to set specification of assay, fisdolution and related substances?

932


give clarity of linearity and range in method validation

2475


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

2015


Why we check moisture,ash & AIA in product

1942


Did anybody have method for acetyl cysteine effervescnce tablet

2298


what are the guidelines for analytical method validations?

1150


what is %labelled amount in content uniformity of dosage unit and its calculation?

5303


function of detecter in hplc ,gc and spectroscopy? function of carrier gas in gc?

2721


why we use Dichlorobenzene.nitrobezine.t-butyldi sulhate.for calibration of gc Head space

2332


mode of absorption in alimentary canal?

2434


For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

1964


what is the principle of UV Vis spectroscopy, AAS, ICP OES,ICPAES, ICP-MS and FTIR

9298


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4134


identification is for unknown? qualification for known? reporting for LOQ?

777