Interior Design (21)
Architecture Design AllOther (186) Dear Sir, I got 90kilowat and 3 face for my house.So which cable is the best for my home main line. Thanks Bashir Ahmed e-mail: bcon.ba.bd@gmail.com
2726RCC colums of 15"X9" each, roof height 20.5'ft, total pillars 36 nons. Span between pillar to pillar is 16/20/20 length wise and 16/14 width wise. Total Slab area 8000 sft and plinth area is 1900 sft. beams are 12"X9". kindly calculate load factor per sqft.
ITI,
1 4673In a small scale residential building 13M rod cut by column post. that rod divided by 2 nos or 3nos which is best?
1 4056Structural wall & slab : Binding wire fixing is alternatively spacing is correct or wrong?. binding wire fixing is all spacing is must or not?
2697One House is being constructed by an Civil Engg. all pillars are as per structure, but north side there should be 4 pillars among two at back side were 6" inside from the border and remaining two comes front were placed 1'6" inside. is it ok as per vaastu, else if i alter the alignment what would be the best idea, kindly help me.
2722how to measure 4mm,6mm,12mm,18mm plywood into a cubic meter and how many layers in a cubic meter
HCL, ITI, MSCB, Vishal, Wood Paker,
3260
how much steel required for 1 sq area for swimmin pool construcion
how to know low voltage and high voltage ranges for electrical machinery ?
what is the difference between R/3 Number range and CRM range?
What are some difficulties of being an interior designer?
In informatica by using filter tranformation what is the filter condition to display for the single id empno
ssc cgl 2010 may tax assistant ki cut of kya hogi
details about telephone wiring
difference between action and collaboration in object oriented designing and modeling
What is the more accurate formula to convert wet concrete to dry aggregate instead of the 54% method?
how much steel bar required for 1 sqm area
is ther a requirement for lintel to be casted in 200mm thick siporex block? kindly mention the advantage and disadvantages?
One House is being constructed by an Civil Engg. all pillars are as per structure, but north side there should be 4 pillars among two at back side were 6" inside from the border and remaining two comes front were placed 1'6" inside. is it ok as per vaastu, else if i alter the alignment what would be the best idea, kindly help me.
Dear Sir, I got 90kilowat and 3 face for my house.So which cable is the best for my home main line. Thanks Bashir Ahmed e-mail: bcon.ba.bd@gmail.com
rate for 5" thk rcc slab using rebarring in pune
What feature is unique to the Hagia Sophia?