Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

Torrent Pharma Interview Questions
Questions Answers Views Company eMail

how calculate column dead volume in hplc ?

3 21369

why 0.005 M sulphuric acid is used to calbrate spectrophotometer and why caffiene is used for calibrating hplc

2 20906

When we calculate Impurity against impurity std.solution and when we calculate impurity against diluted standard with applying RRF?

2 10668

in dissolution why pool sample needed? in which type of drug pool sample need?

2590

what is basc principle of the HPLC,IR,UV AND GC? what is difference between diffusion spectra and transmision spectra in IR?

1 20377

plz tall me that any pharmacopeia and guideline is par meted to use 1.68,4.01,7.00,9.00,12.45 buffer for ph meter calibration

2 3806

what is the difference payment terms in company codelevel and purchase organisation level

1 11858

how much wave length of Soduim vapour lamp used in polarimeter

2 9636

Relation in between KWH & KVAH for Electrical consumption unit & how we can relate if KWH is lower than KVAH

11 138989

IN DISSOLUTION WE ARE USING A LETTER 'Q' WHAT IS MENT BY Q

5 12718

Why we use basket in place of bowl in dissolution apparatus

3 8478

Why 1800 ml of dissolution media used In Carbamazepine ER USP Tablets But other drug only 900 ml Media Used ?

1 4689

Diff between Earthed & Unearthed cable ?

1 4263

what is the balance drift?

2 10581

HELLO FRENDS ,, I M IN THE MIDST OF TROUBLE .. JUST LITTLE HELP ME... SUPPOSE ,, I HAVE A CLOSE VESSELE TANK ( HEXANE MEDIA ) ,, I M USING ROSEMOUNT 2051 DPT FOR LEVEL APPLICATION .. ITS CALIBRATE RANGE IS.. . 0 TO 950 MMH20 ..I DID CALIBRATED DPT WITHOUT REMOVING IMPULSE LINE OF HIGH AND LOW TAPPING.. & WITHOUT DISTURB 3 WAY MANIFOLD..!!! BUT ,,, DURING CALIBRATION I SELECT RANGE BY HART LRV IS 900 MMH20 & URV IS 1300 MMH20 ,, BUT ,TANK LEVEL SOMETIMES 100 % AT 1100 MMH20 , SOMETIMES 1300 MMH20 ..IN THIS CONDITION .. WHOLE LOOP FAILED ,, MAIN THING IS THAT ,, HOW TO CUSTOME RANGE SELECT ?? AND IF I USED RANGE OVER THE ORIGINAL CALIBRATE RANGE ,,,THEN WHAT ERROR WILL BE COME ??? HOW TO ZERO CALIBRATION OF DPT... HOW TO ZERO TRIM BY MANIFOLD ?? AND FOR TANK LEVEL PURPOSE ... WHICH UNIT I CAN USE ??? IS THERE ANY CALCULATION OR CALIBRATION .. IF YEH .. THEN PLZ JUST GIVE ME CALIBRATION STEPS FOR DPT.. THANKS YOURSSSSSSS

1 3764

Post New Torrent Pharma Interview Questions




Un-Answered Questions

Explain how do I limit the maximum amount of messages the smtp queue can hold?

511


what is the difference between Tally ERP 9 and Tally 7.2?

629


What is the melting point of e70 steel, 304,308,316 stainless steels?

494


Hi Guy's Pls. go to Forum of Allinterview.com for Testing Job Openings..You can find various job openings in Forum. You can submit ur resume too

1593


i applied for c licence with my one year apperents trainee and i have attaced with A grade contractor company experiance that is for 14 monts experiance this document is sufeicant for c licence? pls tell why they rejected

1697






how can we find thae value of capacitor for single phase motor. what is difference between starting capacitor and running capacitor.

1880


Which unix shell is best?

535


What is the difference between wordpress posts and pages?

116


Tell me what is world wide web?

443


What is a framework and what are the frameworks available in rc?

536


Explain by-group processing?

585


What is symbolic account?

545


where you want to see yourself after 5 year?

1743


How do you clear a list in c#?

488


What is asp model?

529