how calculate column dead volume in hplc ?

3 21355

why 0.005 M sulphuric acid is used to calbrate spectrophotometer and why caffiene is used for calibrating hplc

2 20883

When we calculate Impurity against impurity std.solution and when we calculate impurity against diluted standard with applying RRF?

2 10653

in dissolution why pool sample needed? in which type of drug pool sample need?

2581

what is basc principle of the HPLC,IR,UV AND GC? what is difference between diffusion spectra and transmision spectra in IR?

1 20362

plz tall me that any pharmacopeia and guideline is par meted to use 1.68,4.01,7.00,9.00,12.45 buffer for ph meter calibration

2 3790

what is the difference payment terms in company codelevel and purchase organisation level

1 11845

how much wave length of Soduim vapour lamp used in polarimeter

2 9627

Relation in between KWH & KVAH for Electrical consumption unit & how we can relate if KWH is lower than KVAH

11 138908

IN DISSOLUTION WE ARE USING A LETTER 'Q' WHAT IS MENT BY Q

5 12702

Why we use basket in place of bowl in dissolution apparatus

3 8456

Why 1800 ml of dissolution media used In Carbamazepine ER USP Tablets But other drug only 900 ml Media Used ?

1 4675

Diff between Earthed & Unearthed cable ?

1 4258

what is the balance drift?

2 10554

HELLO FRENDS ,, I M IN THE MIDST OF TROUBLE .. JUST LITTLE HELP ME... SUPPOSE ,, I HAVE A CLOSE VESSELE TANK ( HEXANE MEDIA ) ,, I M USING ROSEMOUNT 2051 DPT FOR LEVEL APPLICATION .. ITS CALIBRATE RANGE IS.. . 0 TO 950 MMH20 ..I DID CALIBRATED DPT WITHOUT REMOVING IMPULSE LINE OF HIGH AND LOW TAPPING.. & WITHOUT DISTURB 3 WAY MANIFOLD..!!! BUT ,,, DURING CALIBRATION I SELECT RANGE BY HART LRV IS 900 MMH20 & URV IS 1300 MMH20 ,, BUT ,TANK LEVEL SOMETIMES 100 % AT 1100 MMH20 , SOMETIMES 1300 MMH20 ..IN THIS CONDITION .. WHOLE LOOP FAILED ,, MAIN THING IS THAT ,, HOW TO CUSTOME RANGE SELECT ?? AND IF I USED RANGE OVER THE ORIGINAL CALIBRATE RANGE ,,,THEN WHAT ERROR WILL BE COME ??? HOW TO ZERO CALIBRATION OF DPT... HOW TO ZERO TRIM BY MANIFOLD ?? AND FOR TANK LEVEL PURPOSE ... WHICH UNIT I CAN USE ??? IS THERE ANY CALCULATION OR CALIBRATION .. IF YEH .. THEN PLZ JUST GIVE ME CALIBRATION STEPS FOR DPT.. THANKS YOURSSSSSSS

1 3755

Post New Torrent Pharma Interview Questions




Un-Answered Questions

How do you execute your tests from windows run command?

1441


Why dml compiler is significant according to you in a database management system?

298


What are the differences between chemical and electrochemical corrosion? : Electrochemistry Corrosion

591


How do I change directory in cmd to desktop?

505


What are the advantages of sap xi over other tools?

5






How many pins are available in arduino uno board?

5


justify your suitability for this position?

2351


Explain state records?

500


What is the function of ctrl end?

142


Explain on a session in Blue prism?

177


How would you deal with the older members of the organization who are adamant but have to report to you?

611


What is an associative container in c++?

536


What is Sequence clustering algorithm?

1522


What are the default settings of left and right margins?

331


What is the function of socket?

504