Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

Piramal Healthcare Interview Questions
Questions Answers Views Company eMail

why should we give u job ?

24 39880

Why only Water & Sodium Tatrate Is Use For THe Calibration Of Karl Fischer Titrator?

16 103782

What is the Range Of Infra red Spectrum?

5 10113

why we r used APFC Panel in industrial area.when P.F. low then wat will be the effect in our system?

10 36916

we are using three transformer 33000/430 vac for three separet block.all three transformer have three LT panel separetly. can be Interconnected all three panel through bus coupler. this is permissable or not by state electricity board.

4 5079

what is the full form of OTC?

11 28503

any meter avilable for measureing the Transformer Losses. ( like Voltmeter for voltage & ammiter for currenr )if yes plz give the make & supplier address, Email, Phone number.

1576

hi can you give any body fault level calculation, generator fault level calculation,transformer fault level calculation for system fault level with equation? i have 3.3kv generation voltage three gas gen sets, one is 1.9MW,2nd is 2.5MW,& 3rd is 3.8MW & i have 11 kv generation voltage one gas gen sets is 3.8MW, we are step up to 22kv by transformer

3 6634

what is the effect of power factor in electrical circuit ? if we mainten power factor near about unity (0.999) our energy consumption Units increase or decrease?

11 12826

What is diffrence between residue on ignition and sulphated ash?

37 191364

Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1638

what is sink condition in Dissolution?

11 106422

how can you define the PH

17 17945

What is serialization?

5 6696

why are not used methonol in kf titrator to find out water content in ketones?

5 13011

Post New Piramal Healthcare Interview Questions




Un-Answered Questions

What is a multivibrator?

596


what are interfaces and Abstart classes

1439


Define sets?

171


How is it possible to get the total number of arguments that are passed to a function?

521


What is tds and how it is calculated?

580






Tell me your strengths and weakness

669


What causes diesel engine to automatically stop?

1546


Tell me in which of the software testing phase is qa involved & qc not involved?

582


What do you understand by the term directory submission?

424


What are the disadvantages of debentures?

568


How does angularjs dependency injection work?

451


Hi all, Can you please send me the Dimensions and fact tables which are used in mutual fund project. and please send me the brief summary about the project. Please do the needful.

1821


Under what circumstances you will leave this job?

741


How to restart a wpf application programmatically?

209


Why function is used in sql?

498