Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

Energy metering: On the property I am renting, the supply voltage is 2 x 110 volts. These 2 x phases enter a energy meter which then exit the meter to over head lines to my house. Question 1. The meter is single phase 240 volts but is being used as 2 x phase(2 x 110volt), is this acceptable? if not, please give me the reasons. The meter details are as follows: 60Hz 15amp Imax 100 amp Kd 3,6 Wh/R 1 fase 3 hilos Model FX 231. I think it was manufactured in Brasil From this meter, the cables run along over head aluminum conductors,I estimate the cross sectional area to be 25mm diameter, but the neutral is only about 10mm square diameter, which cover a distance of 170 meters and then terminate with an underground cable of 65 meter length, total length = 235 meters. There must be a huge voltage drop over this length. This line is protected with 2 x 200 amp aluminum fuses after the meter, there is no main switch in the distribution board. These 2 phases connect directly onto 2 busbars. Surely the neutral should be the same size as the conductors if not more? Question2. What are your thoughts about this installation, should there be better protection, is the neutral too small? During the night, the lights dim then brighten all the time, this cannot be good for my electrical appliances. In my home, I only have a small electric geyser and fridge, my stove works off gas. But when i use other appliances like the washing machine or microwave oven, the light dim. The internal wiring of this house is done with solid hard drawn copper wires and of course, they have to be under rated. I am a retired electrician by trade, but not on the metering and over head mains side, my experience is on the factory maintenance side of things. Your expertise on these matters will be greatly appreciated. Please inform me how to rectify or make any improvements Kind regards, my power bill is very expensive, so I need to know how to bring it lower. Kind regards, Brian

1 3461

in a live circuit with a light bulb such that the bulb is off by a switch, is the light glows if the switch 2 terminals are both touched by a mouse?

1 3532

why power of fm is weaker than am?

1 3524

how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

1924

in an electronic tri vector meter when the current and voltage sequence changes ? what is the effect of phase sequence on recording of meter

L&T,

2241

what is the difference between 3 phase 3wire &3phase 4 wire meter?what is the advantage of 3p3w over 3p4w?

L&T, MahaDiscom,

1 17940

how to calculate the fault in substation

2462

wow to calculate the transformer rating(KVA)

2274

in 33kv line how much current will be

3 29326

what is the condition for YnD11

Bhel,

2560

how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating

2415

what is sevice settings for mccb?How can be it setted?

2236

why sielent pole is used only in hydro generators and not in turbo generators

1 4188

any idea abt REVERSE METERING concept.........?

2247

2 v/500amp/hr to 1.80vpc at 20 degree celsious 2v/5ooamp/hr to 1.75 vpc at 77degree farren .this is the capacity of a battery .what is the meaning of this . can i get a detailed explenation

2302


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

my UPS suddenly goes off and all panel light also blow off.This happens even main electric supply is not interrupted.After some time it automatically starts functioning normally.Batteries are new.

2067


how to test the turn ratio of 3 phase transformer using volt meter shoe the curcit diagram.

2461


in dc shunt motor if field winding is shorted then

1850


What is miller crystal oscillator? Explain its operation?

1116


we can run 2phase as 3phase .what will be the differnce with respect to phase angle, power, current between the two modes

2219


I have motor of 3 H.P. How i found the rating of capacitor use in it in single phase motor..???

2638


What is Tachometer used to measure?

1254


Name two types of electrical analogous for mechanical system.

1216


How we can recongnise the phase displacement of transformer connection between primary & scondary...plzzz explain it with example.........

2513


Why i receive the GCU fault in my DG Sychronization panel . what all the factors considered for this fault .

2234


What is inverse definite minimum time lag relay? Where is it use?

2825


1.how many earth pits are required for 1000 k.w plant include substion , transformer ? 2. how many earth pits are required for 500kva generator.what is formula to calcute?

2918


hi friends this is a newcomer in your community of enthusiastic peoples. i am preparing for SSC (CPWD JUNIOE ENGG EXAM FOR ELECTRICAL) pls guide me on the same how to crack it? PLS LET ME KNOW IS ANYONE THERE WHO PASED IT? CAN I GET THE QUESTION PAPERS OF PREVIOUS EXAMINATIONS?

2241


What do you mean by an instrument transformer?

1087


If we need 4c× 50mm sq cable but it's not available so we can pull 4c×25mm sq two cables?

1421