If you don’t have coal, salt and copper, then how would you earth your connection temporarily at a campus site?
2 4066If you don’t have coal, salt and copper, then how would you earth your connection temporarily at a camp site.?
2 8508what is the resultant phase shift in a 3 phase power system including neutral if on or more phases gets grounded or short circuited. kindly explain in detail for the reasons...
1 4981is that a problem if i connect a single phase load to a secondry delta connected transformer but i get a neutral from other transformer i the system?
1407If you don’t have coal, salt and copper, then how would you earth your connection temporarily at a camp site.?
1 3992Why tripping not occur when the transmission breaks? Doesn't we provide earthfault protection for it?
1 2782Post New Electrical Engineering Questions
What is the difference between solid grounding and impedance grounding?
What is capacitance?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating
What Normal(Tangent) towers and Tension(Cut-point) Towers?
Why HT 11 KV Slipring Motors are connected in star ?
Advantages/Disadvantages of earthing of neutral bus on MSB instead of separate neutral earthing for transformer/DG sets feeding to MSB
in science exhibition how lamp can blink when you clap near the lamp ? thank you
ow can i get certificate of competency as electrical supervisor and my diploma in electrical engineering from jalgaon.
When we have earthing mesh or underground earthing network in industrial plants, weather we have NT-S or NT-C-S kind of earthing system, so eventually weather we must use 4 or 5 wire in 400 volt level (For example 3×150+70 mm2 or 5×150 mm2) in this connection I would like to know exactly the paragraph of IEC or IEEE number
how to select diiferent power transformers of same capacity on no load loss and full load loss by economical point of view.?
what is your majour contributions in your present job
what is the Pickup/drop off ratio in BCPU relays
# 4 hi friends i m from electrical branch and seeking for tech. + apti. both papers of hpcl plz get it available as soon as possible my email id is sumit_lig189@yahoo.co.in
in ACB breaker requireding 3200Amps. buscoupler getting OFF mode and again it reset and getting normal position give me a required answer?
A Question Like A Wire Is Wound Whose Resistance Is Some 132. 44647 Ohms. If A Voltage Of 30 mv, 296 Ma Current Is Applied To It What Is The Resistance.