plz send me Bhel, Mahagenco, sbi previous exam paper for electrical engineer on my email-id kambali_smita@yahoo.co.in
Bhel,
1927In Transmission System if the potential difference at the two end of line are same then is the transmission of power will continue ? if yes then how.
IOCL,
1 1602WHAT WILL HAPPEN IF WE START A MOTOR WITH STAR & IT IS RUNNING WITH STAR CONNECTION INSTEAD OF DELTA
3 6237What will be the excat cable specification in Sq MM...please find the details below.... Induction Motor HP:55 Amps:70(starting Amps),45(Running Amps). Volts:415
1 5376How we calculate the current carriying capacity of the different sizes of Aluminium busbar ?
3 12311if the supply voltage increased by N times, the x-section of conductor will be.........
APGenco, Electrical Tech, Ericsson, IES, Thirumalai Chemicals,
2 5287Post New Electrical Engineering Questions
direction of tarbine& genrator
We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?
Why we make earth connection with Transformer Body and What will be the minimum size of copper wire as per code with respect to KVA rating of Transformer?
If we use 250A MCCB as a incomer in Control panel for a fault level of 50kA for one second ,assuming temperature rise from 85 Deg. to 100 Deg , Then what will be the Aluminium Bus-bar size for 250A MCCB? Explain in detail.
Draw the line diagram of diffretial relay connected to transformer?
please send privious years question papers of jindal steel and power ltd.My e mail id is rajanikant.sngh@gmail.com
What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.
How RTCC panel is working and give single line diagram for RTCC with transformer?
HOW WE CAN REDUCE THE CIRCUIT COMPLEX OF STAR-DELTA STARTER .BECAUSE NOW WE USING ONE TIMER RELAY & THREE CONTACTOR FOR MAIN,STAR & DELTA ?IF ANY IDEAS PLZ POST.THANK U
Advantages of using generator circuit breaker (GCB) scheme in a power station ?
What is size 00, 01, 1 etc., in HRC fuse types?
typically in power distribution substation. 1- Any idea how would be the graph of capacitor bank consumption verses time through the day . 2- How is the switching ( on and off ) of the capacitor bank, per need?
3 phase Motor will be given 2 phase after 2 to 5 second we given 3rd phase so Motor Run sum-time in forward or sum time run reverse direction. All time phase sequence is not change. Why motor run in reverse direction? Please Explain........
what is invertor supply and raw powersupply
how to determine the cable size...pls explain me with the formula taking particular load....does the factors like impedance & short circuit rating influence the cable size, if so how....