Electrical Engineering Interview Questions
Questions Answers Views Company eMail

why lightning arrestor are made by 2 stack of insulator but why cvt are fully 1 stack of insulator.

1 3567

why we are maintain phase to phase clearence

4 5435

why generation of electricity in low value voltage

3 4462

why the insulators are in cofee colour???

Visa Steel,

4 11150

why the tapping of transformer on ht side??????

CTS, OPTCL, Visa Steel,

12 38697

what is maintenance?how to explain

1455

cable selection formulas for electrical load.

Bhel,

1 7491

megger how much voltage will produce ?

4 7972

How to identify the start and end of 3phase 12 lead motor if U1, U2, etc numberings are lost or erased.

1714

what is creepage distance

2 8730

what is the working principle of energy saver control panel. please give the complete calculation & theory.

Lupin,

1835

For what purpose an AVR in generator sensing generator output voltage?and how the sensing is done by AVR?

3 7937

Is it possible to measure correct value of earth resistance & cable insulation ristance with out disconncting earth lead & both sides of cable ends? If not, any other method to measure ER & CIR with out disconneting from the system.

HAL,

1653

Is it possible to use AC supply insted of DC supply in trip coil operation? if not, why?

HAL,

5 6032

How to do cable earhing? whether by grounding Armour to ground or by running extra G.I wire along with cable? which one is preferred mostly amoung them? If the second one is more preferable how many GI wires to be run along with cable (1 or 2)?

HAL,

1592


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

I want to know the 'Test voltage' for Tandelta testing of 3.3 / 6.6 / 11 KV Motors. Please explain

1787


send me any model test paper of clerical post of state bank of india.......

1381


What is the maximum number of swithes that can be connected in series up to down stream point in an LV Distribution system?

1531


What is power in wattage of 8.5 TR AC

1191


As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?

1199






What is difference between safe PLC and normal PLC

996


How many types of probe used in cro?

663


Why we make earth connection with Transformer Body and What will be the minimum size of copper wire as per code with respect to KVA rating of Transformer?

1295


where does 22kv line starts

2671


what are problems caused by the pdu in rack server

1460


what is arc flash and what are the hazards involved

1671


why motor range is available 22kv,30kv,37kv,45kv and so on? why motor range is not available 21kv,24,25,26,27kv and so on?

2363


Why is the frequency not changed during transformation of electrical energy in a transformer?

849


What is real time power factor control panel(RTPFC)?

3830


why we use single core 630mm2 cable for transformer secondary side

485