Electrical Engineering Interview Questions
Questions Answers Views Company eMail

I WANT YHE TECHNICAL AND ELECTRICAL SPECIFICATIONS OF 2x4MW 11KV 2x10MW 11KV 2x25MW 11KV 2x100MW 11KV HYDEL POWER PLANT i.e PROTECTION SYSTEM,MONITORING,CONTROL SYSTEM,GENERATION,SYNCHRONISATION,METERING PLEASE SEND THE DETAILS TO MY MAIL ID SPRAVEEN_222@YAHOO.CO.IN

1657

Can 4pole (3 phase+neautral )RCCB proper functioning in only 3 phase load (no neautral, no Earth) ?

HCL, Reliance,

1703

how can we decide where we have to DYn11 or other vector group transformer

BSL, Knight Frank, Security Printing and Minting Corporation of India Limited,

4 30430

What is polarisation index value?.(pi value) Simple & brief definition of polarisation index?..

7 17117

What is the field weakening mode of a ac motor?

L&T,

1 2230

Please clarify 1. Icw: rated short circuit working withstand capacity 2. Icu: Rated ultimate breaking capacity 3. Ics: Rated service short circut withstand capacity 4. other specification of ACB

2291

What is an Air COmpressor

DLF,

1720

what r Grid stations?what r there role.Explain in detail

1 1963

explain how the power is distributed from a power plant to a consumer.explain step wise in detail

1 3572

what r substations?what r there work?why voltages r incresed and then reduced during distribution of power

1467

The transmission does not have options: a)Partition noise b) Flicker noise c) resistance d) Short noise and reason

1939

* Signal transmission in sky wave propagation is due to ? a) Reforction of wave b) Reflection of wave c) Pierus through Inosphere d) None and Reason for this is????

2 5129

Single line diagrams for star to delta and DOL starters.

1813

what is bus duct and what is differance between bus duct and bus bar

6 47140

in gen traf what is ONAN , ONAF , OFAF and DYN

3 8972


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

What is shunt voltage and u v voltage witch one best

1293


what is the difference between oil surge relay and buchholz relay.

6427


Did RMU have ct and pt ?

946


How can I calculate the Mega watts required to run a plant having many electric motors and other electrical components.

1667


what are the condition that makes hooter blow?

1864






What type of pipe material G.I or M.S is used for sprinkler system?

8330


what questions are asked in the interview for the post of an electrical maintenance engineer in FMCG companies?

2148


in dc series motor if field wdg is shorted then

1437


I want to know all basics of electrical engineering

1436


In hydel power plants, L.A's, S.C's are placed inside the control panel boards. what is the purpose? [already the total body was earthed to ground.]

1446


What is the direction of current flow in ct secondary...means if the current is flowing from P1 to P2 then what will be the direction of current flow in ct secondaryw

1411


What are hrc fuses and where it is used?

731


What is “pu” in ee?

646


As per the Anchor capstan motor specification, full load current is 200A. starting current is 1750 A and acceleration time is less than 8 seconds. Please guide for selection of cable size.

1435


i want to put single phase load on scott connected transformer,eventhough how to balance the transformer.

1412