I WANT YHE TECHNICAL AND ELECTRICAL SPECIFICATIONS OF 2x4MW 11KV 2x10MW 11KV 2x25MW 11KV 2x100MW 11KV HYDEL POWER PLANT i.e PROTECTION SYSTEM,MONITORING,CONTROL SYSTEM,GENERATION,SYNCHRONISATION,METERING PLEASE SEND THE DETAILS TO MY MAIL ID SPRAVEEN_222@YAHOO.CO.IN
1657Can 4pole (3 phase+neautral )RCCB proper functioning in only 3 phase load (no neautral, no Earth) ?
1703how can we decide where we have to DYn11 or other vector group transformer
BSL, Knight Frank, Security Printing and Minting Corporation of India Limited,
4 30430What is polarisation index value?.(pi value) Simple & brief definition of polarisation index?..
7 17117Please clarify 1. Icw: rated short circuit working withstand capacity 2. Icu: Rated ultimate breaking capacity 3. Ics: Rated service short circut withstand capacity 4. other specification of ACB
2291explain how the power is distributed from a power plant to a consumer.explain step wise in detail
1 3572what r substations?what r there work?why voltages r incresed and then reduced during distribution of power
1467The transmission does not have options: a)Partition noise b) Flicker noise c) resistance d) Short noise and reason
1939* Signal transmission in sky wave propagation is due to ? a) Reforction of wave b) Reflection of wave c) Pierus through Inosphere d) None and Reason for this is????
2 5129Post New Electrical Engineering Questions
What is shunt voltage and u v voltage witch one best
what is the difference between oil surge relay and buchholz relay.
Did RMU have ct and pt ?
How can I calculate the Mega watts required to run a plant having many electric motors and other electrical components.
what are the condition that makes hooter blow?
What type of pipe material G.I or M.S is used for sprinkler system?
what questions are asked in the interview for the post of an electrical maintenance engineer in FMCG companies?
in dc series motor if field wdg is shorted then
I want to know all basics of electrical engineering
In hydel power plants, L.A's, S.C's are placed inside the control panel boards. what is the purpose? [already the total body was earthed to ground.]
What is the direction of current flow in ct secondary...means if the current is flowing from P1 to P2 then what will be the direction of current flow in ct secondaryw
What are hrc fuses and where it is used?
What is “pu” in ee?
As per the Anchor capstan motor specification, full load current is 200A. starting current is 1750 A and acceleration time is less than 8 seconds. Please guide for selection of cable size.
i want to put single phase load on scott connected transformer,eventhough how to balance the transformer.