Instrumentation Interview Questions
Questions Answers Views Company eMail

TEMPERATURE VARIATION FOR FREQUENTLY.

TVS,

1507

why we set -10 volt in vibration sensor output,why not +10 volt

Sabic, TVS,

3 23170

How does a strain gauge measure pressure?

2 4770

How can corrosion alter the accuracy and precision of a C- Bourdon tube pressure gauge?

1 2797

How do bending tubing provide better measurement than using tubing fittings such as elbows?

1476

How to get Cv of control valve having following parameter ,i.e inlet pressure 4.5kg/cm2 outlet pressure 1 kg/cm2 specific gravity 0.808

3 5623

how radio frequency level probes works with its controller ? what is its principle ? pls give me brief explanation?

1389

why generation of syncronized generator increases when frequency of grid is less then 50Hz & generation decreases when grid frequency goes up from 50 Hz, as comparision with set value entered in govering panel?

1 2993

Can anybody tell me application of PLC,DCS,SCADA.

Reliance,

3 7646

Hi..i am B.E. (elect.&comm.)..i m workini in a bio mass power plant as inst. Engg. I want 2 know about growth in big power plant sector..is this field is good 4 me ..i m electronics engg..? Plz plz reply..

Reliance,

2 4626

modbus and profibus communication difference?

1 9400

how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?

5220

In control valve there are two type of valve seat we can use metal to metal seat & soft seat.On this valve seat i have following doubt. 1)I have never seen practically the internal assembly of valve so my doubt is that basically weather the seat is soft seat or metal its basic MOC is same as valve body(SS or CS) only in soft seat we are using PTFE ring & place on valve seat & in metal this PTFE ring is not threr am i correct??????? 2)what are the common general rule for using metal to metal seat & soft seat,means its depend on process parameter like liquid,gas, steam & on valve leakage class.

1 1877

In case of Transmitter's(e.g.Ultrasonic Flow meter ) we have an normal practise of selction of upstream and downstream distance such as (20D and 5D ).can anyone please let me know whow to calculate "D" ?? i guess it refers to pipe thickness is t right ?

2 3742

a flow transmitter [range-0-400mbar] connected in process line. please explain me how to calibrate the flow transmitter , & how to do static error

L&T,

1839


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?

1722


what is easiest way to read STL language in PLC?

2653


What is difference between “Fault Tolerant” & “Fault avoidance” PLC? Application where these system s are used?

3436


Any one can help me to identified, how can we interchange the device in FF

2310


Explain the difference between plc and cnc?

551






sir, i preparing hpcl,ongc,barc,hal exams(instrumentation engg)pls send a placement papers

1861


the pump holds on run indication into the dcs and filed local control panel remote push button condition operaton wrong like when the push button pushing conditions the pump is off and the push button release condition the pump is on totally opposite condition . And control room inside give the stop command into dcs just 1secon relay engage and again normal condition. How can I slove

1126


principle of dead weight tester ?

1596


How to Calibrate Temperature Switch in field

793


Galvanizing.

1462


we want to control pump in let pressure and tank (for exp) our inlet line if water cam and pump will on and when our tank will full pump will off also if our inlet pressure low pump will off even tank not full.this pump i want to uses on our water supply line.

1277


Why thermo wells are used? What materials are used in thermo wells?

646


We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.

1748


what is the difference between scaler and vector drive

1655


can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).

1592