what do u mean by compensation n pid tunning?in pid tunning what you tunned?is it possible 2 tune p i d
2 5407how u meassure room temp?is it possible 2 meassure room temp by rtd or thermocouple?between rtd n thrmocouple which is more regard?3 meassure diff. between rtd n thermocouple?
3 6594what is axial shift n what is differential expansion in turbine? how many sensor probes r mounted for this n how it works?
2 33211basic connection and principle of axial shift sensor n differential sensors in tubine describes n draw......
2373what is the reason for flow fluctuations happen on differential flow transmitter during in service
2 5900what is the path to communicate from profi to ofc.what is the means of communication.what is multi cire cable in ofc.
1 4122Post New Instrumentation Questions
I need to know steps to Calibration Valve Guard......
Definition of reverse and acting controllers:
How ejector(or)evactor air pump is working in thermal power plant?
what is the reason while warning lamp is on while the engine is cranking?
what should he know if he is an assitent engineer instrumentation in cement industries of experience of 10 - 15 year.
Explain why plc require in analog input 4-20amp & 0-10 volt?
i am from instrument branch i want paper patern of mahagenco . any pevious years paper regarding my branch send me please . please.....
How to check vortex flow meter is in good condition while we do not having calibration setup?
I am manjunath having exp in maintenance of chemical plants,know i want to do a design course INTOOLS,after doing design course can we get jobs in design field.sinve i dont have design exp..
What is instrumentation instrumentation engineering?
how do i tune dearator pr control valve using PID. we set the set point is 0.6kg/cm2 now i want 0.5 to 0.7kg/cm2 limits so what should i give p,i,d values. then pls explain how do set pid values for control valve tuning?
what is the process to make control schematic ?
we want to control pump in let pressure and tank (for exp) our inlet line if water cam and pump will on and when our tank will full pump will off also if our inlet pressure low pump will off even tank not full.this pump i want to uses on our water supply line.
In bently nevada vibration monitoring system,what is the reason to maintain the Resistance of the probe + extension cable equal to 95 ohm? If possible explain the basic principle of measurement with detail electronic circuits.
Why even multiple power supplu r used in instrumentation system?