Instrumentation Interview Questions
Questions Answers Views Company eMail

hello i'am samad.Any one Can help me! How to calibrate Vaccum Transmitter DP Type range 0 - 50 mbar abs by hand pump calibrator.

Bharathi Cement,

4 4620

Why Pressure Transmitter is NOT installed before up-stream of an ORIFICE PLATE? in a flow measurement.

Mecon,

4 7470

How RAL(Rotary air lock)works in cement industry?

Jaypee,

1967

What is the procedure of calibration of Load cell?

1496

How works weighfeeders in cement industry? what is the working principle?

1526

Describe the function of Accumulator into the Pump

1488

Which mechanical device is used in pressure gauges to reduce pulsating

4 5845

what effects a surging can produce in the compressor

Nemat,

1476

NSV type probe stands for

Qatar Petroleums,

1972

what is the function of 3 way manifold valve in a closed loop system?

Emerson,

1 12209

what is the difference between laminor flow and turbulant flow

Invensys,

2 6008

What is the main three inputs of DCS?

1 5895

What is the meaning of Feedback? How many types it is? Explain it?

Bharathi Cement,

2 5096

What is PDS and PDMS ?

1701

Why we are using DPT(Differential Pressure Transmitter) in separator instead of level trasmitter?

1781


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

PT RTD Range: -200 to 500 degree celsius If I configured in DCS Lower range and Upper range . In face plate it shows red colour due to overa range how was the characteristics look If the temperature is more than operating range. how was the characteristics look . whether its in Resistance vs Temperature curve is Linear or Non linear

1538


what is interface level measurement.who can calibrate interface level measurement transmitter online

1985


In which principles tx ,pressure gauge,Temp gauge,control valve works?

1297


what is function of sensor, and how is it work , explain with difination

1895


POSSITIVE PULSE IS APPLIED TO AN INVERTER INPUT.THE TIME FROM THE LEADING EDGE OF THE INPUT TO THE LEADING EDGE OF THE OUTPUT IS 10 ns. THE TIME FROM THE TRAILING EDGE OF THE INPUT TO THE TRYLING EDGE OF THE OUTPUT IS 8 ns. WHAT ARE THE VALUES OF tPLH and tPHL?

1763






Where are oxygen analysers installed in cfbc boilers? What are their usual readings?

1127


Why the ammonia and Nitric Acid level indicators is with millimeter ? and What is the conversion form millimeters that level indicator indicate to weight ?

1224


Why boiler chimney area  oxyden sensor fixing? 

2050


how to change measuring units from mmwc to cubm/h in rosemount air flow transmitter with hart communicator fluke 744

1929


What is offset in a control system.

7969


There are many type of control cable like pair,core,tried, What are defination each one

1740


please can any one tell me clearly about pid tuning i am confusing about this .how to tune pid easly?

1694


Sir , i have completed my M.Sc In Instrumentation and presently working in Maintenance department 3 yrs Exp , is there is any possible for work in offshore ..

1400


I want measure the volumetric flow of gas in waste heat recovery Boiler?Tell me how and which type of instruments required. Plz mail me:naba02222@gmail.com Sam please post the answer .

1561


how to design orifice plate?what is the equation?

1634