Instrumentation Interview Questions
Questions Answers Views Company eMail

GIVE BRIEF DESCRIPTION ABOUT "DCS"

2 4712

List three types Level Gauges with their working principles

ABB,

1641

List three types Level Switches with their working principles

1623

List three types Level Transmitters with their working principles

ABB, Bapco Bahrain Petroleum Company,

1 2538

Difference between 2-Valve Manifolds, 3-Valve Manifolds and 5-Valve Manifolds 3 with diagram

Acire Systems,

2684

y v r connecting 250 ohms resistor in series when u cummunicate with BT in bench calibration?

5 6778

diff bw range and span?

3 5159

plz tell me clearly about PID.."when v have to change I value,D value,GAIN??

1684

what is output of FOUNDATION FIELD BUS transmitter

1694

I work on a electronic positioner transmitter 4211 at the field.I connect my multimeter in series to get the current output then I calibrate it to 4ma in 0% of position of the valve and 20ma in 100% position of the valve.My problem is in the field I get the correct output current based on my multimeter but in the dcs they only receive 40% in a output 20ma of this positioner.Then I try to simulate in this analog card and they receive the equivalent percent on the value that I simulated.Is ther any possibility to reset the zero and span of this positioner 4211 fisher.And what other possibility I can do to fixed this.This is my email add ( landicho_randy@yahoo.com )

4 8010

my data card only does run in my mobile so how can change it that it run other mobile & computer and i can stor data in my data card

1814

i have level transmitter -400 to 0 range for steam drum application but i am unable to calibrate if installation of lt below lower tap what will be the effect ? and as per std wht is location of lt ,above lower tapping or below

1 3795

WE ARE HAVING YOKOGAWA CENTUM CS 3000 DCS, 2 FCS AND 4 HIS " When the operation Download to HIS message appears: Equalize start. HIS0163 WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. HIS0163 ---- ERROR = 3 WARNING = 1 ---- Tell me, please, why and how to solve the problem."

Khas Pvt Ltd, Yokogawa,

6 22753

If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?

QAFCO,

1631

If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , then it will reaches again 50%, this type of action occured frequntly.. so what to do for solve this problem. The possible cause is in volume booster or positioner's relay.. positioner is double acting .. and make siemens..sipart.The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?

Gujarat Fluorochemicals Limited (GFL), Shell,

2 11910


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

How to do gas analysers calibration in AUTO and Manually by using zero and span gas?

1919


hello sir/madam, I,Subramanian need 5yrs placement papers of officer trainee of Instrumentation technology.pls send to this mail id mani_nxtgen@yahoo.co.in please do the needful. with regards, subramanian.v

1766


what is moisture probe? What are there types? What is there working principle and how they works? guys this is one of technical question I had ask in interview. If you know its answer please let me know. The interviewers were more interested in microwave moisture probe, so if you find its any link please just forward me on my mail id.avinash1200@gmail.com Thanks in advance.

1524


Why rdt and thermocouple both give different output .and one things more, how to generate  ohm or mili volt  plz mail me merajalam143545@yahoo.com

2318


how to calculate control valve bonnet size?? or how to select its material?

1951






How will you calibrate an Absolute Pr.Transmitter of range 400mmHg absolute ?

1594


Name different parts of a pressure gauge. Explain the use of hair spring in the pressure gauge.

665


can we copy the software from a transmitter using hht(hart 275) ?

1629


3. Differentiate between ultrasonic flowmeter and radar type flow meter.

2433


Type of level transmitter commnly used in Procees area are the following. a.________________This type of level transmitter works as follows

1644


WHAT IS MEANT BY PROJECT MANAGEMENT STRATEGIES IN INSTRUMENTATION?

3031


How to convert Differential pressure to flow in TPH

1744


Square root calculation for dp flow transmitter?

666


How to calibrate Field bus transmitter? procedure ?

1826


What is profibus?

644