y v r connecting 250 ohms resistor in series when u cummunicate with BT in bench calibration?
5 8477I work on a electronic positioner transmitter 4211 at the field.I connect my multimeter in series to get the current output then I calibrate it to 4ma in 0% of position of the valve and 20ma in 100% position of the valve.My problem is in the field I get the correct output current based on my multimeter but in the dcs they only receive 40% in a output 20ma of this positioner.Then I try to simulate in this analog card and they receive the equivalent percent on the value that I simulated.Is ther any possibility to reset the zero and span of this positioner 4211 fisher.And what other possibility I can do to fixed this.This is my email add ( landicho_randy@yahoo.com )
4 9500my data card only does run in my mobile so how can change it that it run other mobile & computer and i can stor data in my data card
2285i have level transmitter -400 to 0 range for steam drum application but i am unable to calibrate if installation of lt below lower tap what will be the effect ? and as per std wht is location of lt ,above lower tapping or below
1 4790WE ARE HAVING YOKOGAWA CENTUM CS 3000 DCS, 2 FCS AND 4 HIS " When the operation Download to HIS message appears: Equalize start. HIS0163 WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. HIS0163 ---- ERROR = 3 WARNING = 1 ---- Tell me, please, why and how to solve the problem."
6 25829If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?
2100If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , then it will reaches again 50%, this type of action occured frequntly.. so what to do for solve this problem. The possible cause is in volume booster or positioner's relay.. positioner is double acting .. and make siemens..sipart.The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?
2 12966Post New Instrumentation Questions
Turbidity analyzer working principle ?
What is 1:1 redundancy ?
What are primary elements of measuring pressure? Which type of pressure can be measured by these elements?
flow transmeter accuracy 0.075% of full scale & find ucertainty is 0.025 % so what is maximum limit band of uncertainty
What is exact difference between the panel earthing and system earthing in DCS system. What is the value of resistence.
How ejector(or)evactor air pump is working in thermal power plant?
How will you test a transistor with a multimeter?
what is SIL 1 2 3
How we connect a instrument with ground, Give brief explanation with help of diagram?
What is zone,loop/fire alarm system?
What is the use of GMV in turbine?
How would you choose differential range?
How d.p. Transmitter can be applied to open tank?
what are the diff. in servo and regulatory control?
while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?