Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

KPTCL Interview Questions
Questions Answers Views Company eMail

The first telegraph line between Calcutta and Agra was opened in (a) 1852 (b) 1853 (c) 1854 (d) 1855

4 24712

What is Ohms law?

28 35540

check list of maintenance of transformer?

11 113343

HOW DOES ONE SELECT A TRANSFORMER PHASOR GROUP IE, WHETHER A STAR-DELTA TR OR A STAR-STAR OR A DELTA-DELTA, ETC. TRANSFORMER IS MORE SUITABLE FOR A PARTICULAR KIND OF LOAD OR WORKING CONDITION???

3 7821

how to check the earth resistance value& what is the minimum earth resistance for good earthing sysytem.

33 154983

define frequency ?

14 21374

what will hapen if secodery circuit is open of current transformer

8 18585

how can we find a burden of potential transformer? what does it effects? how can we calculate rated load of it?

4 34674

in 400 kv system why should trip both side CB when we give hand trip?

1 7567

how to caluclate tds from emloyees and others

2127

Insulater disk using formula for 33/66/135 line h t line

1 5024

what is broken conductor indication

3 5164

We have 11kV/110V three phase indoor potential transformer in 66/11kV Sub-station, where the failure of PT is frequently happening and the rating of the PT is 0.2 class accuracy, with primary star and seconday (two cores) star connected. Some experts has suggested to not to connect the PT Primary neutral to the ground because when transformer neutal NCT connection is loose; the faulty current will flow through the PT primary neutral, resulting into failure of PT. My question is: Is it necessary to remove the primary neutral connection of the PT from ground? if not, what would be the reason for failure of PT. Please guide me.

2 3768

In my power station 220 volts dc battery set. they coneected 84th cell taped

1 2239

Post New KPTCL Interview Questions




Un-Answered Questions

Can you store images in postgres?

790


postfix expression for x^y^z-m+n+p/q ?

2232


What does statelessness mean?

1037


What language is bash?

931


What is a nested masterpage in asp.net 2.0? Can there be a master page inside a masterpage?

907


How do I enable the f12 boot menu?

614


Why can't I invoke the ResultSet methods afterLast and beforeFirst when the method next works?

1226


How do I insert an xml file into word?

822


Is copper tube withstand under hard water say as 500 TDS.And is it cleanable by solfamric acid or by tube brushing

2220


How can events be prevented from stopping to work after an ajax request?

784


What is the importance of ods in biw?

923


What is the type of the following Array?, val arr = arrayOf(1, 2, 3);

325


What is the importance of Global.asax in ASP.NET?

1156


Explain what is a three tier data warehouse?

982


What is orientation in android? How is it done?

949