why vaccume required in turbine?

Answer Posted / k devanesan

The last stage absolute temp. of steam will be near to
vacuum pressure. To maintain the dryness fraction of steam
in last stage vacuum required in the down stream of steam
flow. so, vacuum need in condenser.(P1V1/T1=P2V2/T2.)in
condenser there is no temp. drop. so P1V1=P2V2. the volume
of condenser is more than last stage area. so, pr. will be
less than last stage pr.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can contractor purchase as cst purcbase who is registerd under wct act in mp

1191


What type of boiler does not need a steam drum ?

648


i want to know how a dg set run/works and what is strock and what difference in between two and four strock engine.

1781


Sir can u send me few interview questions and answers based on Deputy Superintendent(materials) of APSRTC. I have selected in written.reply to bhanudammoju@gmail.com thank u.

1370


What is temper embrittlement in alloy steels and what are its effects ?

628






Define emissivity.

817


What are killed steels and what for these are used ?

633


how we relate superheating & subcooling with chiller load

1730


What are considerations taken into account while creating a piston head?

647


what is tranformer and transducer

1448


How is technology significant in the field of mechanical engineering?

677


How much should be the minimum and maximum suction and discharge pressure of screw chiller plant.

2303


WHAT IS THE TOTAL HEAT RATE OF PLANT AND WHAT IS THE HEAT RATE OF BOILER?

1670


why we open open condenser vacume early when the unit get balck?

1507


Draw the flow of F.O. diagram from service tank to Main Engine?

1812