Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how peak can be sharp in hplc when it is come flat

Answer Posted / shashikumar.v

Add little amount of peak modifiying agent TRIETHYLAMINE

Add 1% acetic acid

Reduce the pH of the mobile phase to < 3.0

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why require to add enzymes in capsules dissolution only? is it require to tablet also?

643


why we use Dichlorobenzene.nitrobezine.t-butyldi sulhate.for calibration of gc Head space

2204


WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?

2524


how pda detector works over uv?

693


What is the Formula for coreletion coefficient in plhplc calibration

1773


Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1744


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1909


What is the difference between Discriminating media and DPDM(Dissolution Profile with Different Media)

7474


Describe your field experience sample type collected,sample techniques,field measurements taken and equipment used?

2649


What is the acceptance criteria for moisture balance when calibrated with sodium sulfate

1985


in which situation ion pair require to use?

744


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3487


in DMF having extra impurities and in api COA also having extra imp than USP or BP product then how require to proceed?

776


how a particular wavelength can be different for a particular compund while analysing by uv and by HPLC.

2247


why cone formation during dissolution?

730