Why chromic acid wash is not recommended by USP for glassware cleaning?
Answer Posted / b.gangatharan
According to USP chapter<1051>chromic acid is not recommended for glassware cleaning due to hazardous &toxic nature of the material.
Thanks,
Gangatharan.b
Caplin point,
Puducherry.
Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
In BP2013, Loperamid HCl monograph. Assay by titration with 0.1N sodium hydroxide using hydrocloric acid 0.01N and reading the volume added between the 2 points of inflexion. I have a question that if the diluent solvent is ethanol is certainly consumed a amount of volume of titrant, so this volume must be eliminated on the result calculation or not apart from first point which is subtracted above.
what is biorelivent dissolution media?
2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.
why are measure gas flow " ml " in Gas chromatography
cefoperozone and sulbactam inj. hplc test method
why we are using hexane in calibration of number of drop per mL
in api coa contains only process impurities and in product coa contains degradation impurities?
What is control room temperature and which guide line says?
what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?
What is the accrptance criteria in RSD for RS method precision on basis of impurity percentages?
In IR spectra, generally a molecule vibrates without apply emr or ir light?
In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?
How can we confirm the HPLC column is end-capped or not? Is it possible to identify by physical appearance?
which one is better separation in high pressure liquide chromatogram orlowpressure chromato gram in hplc
some product having water content method with pyridine and ethylene glycol mixture instead of methanol? how they are selecting and methanol is not suitable solvent how ?