Describe your experience with quality assurance and quality
control analyses?
Answer Posted / abhishek awasthi
Quality Control is a process to ensure a certain level of quality in a product whereas Quality Assurance is a process which determines that whether the product is meets the customer expectation or not. QA is a proactive process.
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
Why we check moisture,ash & AIA in product
From where require to take the RLD sample?
How to determine water content of bis tetrazole amine mono ammonium salt
What is the formula to determine the concentration of M of a solution given the % transmittance? Use %T = 43.7 as an example.
what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?
how to get accurate result for Residue on evaporation in purified water
USP methodology, EP methodology, IP methodology, among three if possible to use one methodology for qualify working standard to use USP, EP, IP ? Please explain...
How require to perform linearity as per ANVISA? What are the acceptance criteria?
pharma industries oriented
My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards
If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately
How we can identify process related and degradation impurity in single method with short period?
For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?
how you fix the limits of impurities?
If we do accuracy at same concentration at which linearity planned,what is the need to do linearity separately?