Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What are the different types of columns used in HPLC

Answer Posted / pramada

Zorbox and Agilent, Inertisil ODS ,C18 ,C8

Is This Answer Correct ?    7 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the formula for relative diffrence for standard solution in solution stability in validation?

815


What is the accrptance criteria in RSD for RS method precision on basis of impurity percentages?

839


In performance Check of GC Why Hexadecane Peak is Considered 

3052


what type of question will ask in the interview of lab chemist.

3328


how you fix the limits of impurities?

847


What is rs test why we are performing rs test?

1872


why we use glass fiber filters use in some situation?

810


What is the Formula for coreletion coefficient in plhplc calibration

1844


what are the guidelines for analytical method validations?

1113


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3674


process of Diclofenac sodium,IP.

2228


How to calibration of the uv spectroscopy and its test?

1205


What is control room temperature and which guide line says?

1655


Which is the highly polar and highly non polar column in HPLC?

2318


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1610