Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the purpose of Buffer in any titration?Ex:In
determination of hardness of water we use ammonia
ammoniachloride buffer in titration with EDTA.Why?

Answer Posted / arhama

buffer solution resist change in PH.

Is This Answer Correct ?    22 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why only hydroxy naphthol blue indicator is used for standardisation of 0.05M EDTA solution instead of solochrome Black T or Euriochrome Black T indicator which is used for all sample analysis with 0.05M EDTA solution?

2733


Loss of linearity in tkn analysis, possible reasons?

1324


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1601


If we do accuracy at same concentration at which linearity planned,what is the need to do linearity separately?

2310


In performance Check of GC Why Hexadecane Peak is Considered 

3047


What is the calibration of uv process and preparation

2000


WHAT IS THE PURPOSE WE USE HCL, CHOPPER, BURNER, MONOCHROMATOR in AAS? PLEASE EXPLAIN BRIEFLY

2616


in which situation require to change rs specification?

754


[3/28, 20:52] Manoj P Venkatpurwar: how many impurities require to inject in assay specificity that how we can find out? and in Rs also how?

795


We use hicrome 10 cxs column in hplc analysis....pls tell me.. what is the meaning of 10 cxs?

1721


effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?

933


how can give the expiry period and restadardisation of volumetric solution

2599


What is the principle of HPLC, GC, LCMS, GCMS,LC QQQ, GC QQQ, LC Q TOF and GC Q TOF. What are the applications and Specificity?

8868


iam usig ph buffers merk. manually how to prepare ?

2280


Qc interview questions

1747