full name of OOS & OOT ? Dercribe it with details ? why
this is needed in pharma industry ?

Answer Posted / arvind mishra alchemist

The two terms out-of-trend (OOT) and out-of-specification
(OOS) results are in many cases confused by pharmaceutical
companies and regulatory agencies. OOT results are defined
as a stability result that does not follow the expected
trend, either in comparison with other stability batches or
with respect to previous results collected during a
stability study (1). OOT results are not necessarily OOS,
but they do not look like a typical data point. Although OOT
results are a serious problem, the scientific literature and
regulatory guidelines do not fully address this issue
Methods for identification of OOT results—the
regression-control-chart method, the by-time-point method,
and the slope-control-chart method—and further compare the
z-score method and the tolerance interval in OOT analysis.
The results highlight the need for issuing a regulatory
confirmed guideline for identification of OOT results for
ongoing stability data.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is %labelled amount in content uniformity of dosage unit and its calculation?

4627


if instrument calibration fails then what require to do?

470


how you establish the LOQ?

313


which one is better separation in high pressure liquide chromatogram orlowpressure chromato gram in hplc

1727


why glutent are detected in the rice cereal baby food product even manufacturer claimed that they are using rice and milk only?we have using ELISA to do the test,and rice supposed not containing any glutent,rite?We already repeat the test so many times and it still detected.just wondering where the glutent came from?

2348






calibrtion procedue of LC-MS

2149


which batch require to use for analytical method validation?

336


in hplc chromatogram started from left to right and in uv spectrum started from left to right

471


analytical method validation require to with respect to release specification or shelf life specification?

284


what is the origin to prepare standard operating procedure

1791


How do we quantify crystaline and amarpous forms by using (NMR, XRD)spectroscopic techniques? Which any others instruments are useful for this quantification? explain

1954


on the basis of bcs class how to proceed the solubility?

285


what is difference in ods I ods II is this is realy from sorbent / packing characteristics or from other means

1495


How to know the estimated LOQ concentration in ppm

739


when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.

1522