Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

differance between L1 and L7 columns

Answer Posted / priyanka.r

According to usp code L1=C18 COLUMN
L7=C8 COLUMN

Is This Answer Correct ?    8 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Difference between the quantitative analysis and qualitative analysis?

1188


using gradient pressure in gas chromatography are not ?using gradient pressure why

3395


How to calculate coreletion coefficient

1718


process of Diclofenac sodium,IP.

2221


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1874


Colorimtry

1669


What is the difference between Discriminating media and DPDM(Dissolution Profile with Different Media)

7552


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1974


which one is better separation in high pressure liquide chromatogram orlowpressure chromato gram in hplc

2165


can i use hplc detector to uplc and why?

2298


Why to use propyl paraben in HPLC gradient calibration

7499


how the compound separate in coulunm,explain

2539


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

864


How much is the standard area for glc analysis

2294


If we do accuracy at same concentration at which linearity planned,what is the need to do linearity separately?

2310