Answer Posted / kiranreddy munnangi
As you all know ,we measure pH of all of samples in
water.And the reaction of water is
H<+ + OH<- ------> H20
In this equilibration constant kw is
[H+] [OH-] = Kw = 1 X 10-14
By applying -log on both sides
-log [OH-] - log [H+] = 14
You know pH= - log [H+]
Therefore, pH = 14 - (-log [OH-])
You can see from this equation that the higher than
concentration of OH- ions, the lower the value of -log [OH-
]. If the concentration of OH- ions reaches 1 mol/dm3 , the
value of -log [OH-] is zero, which, according to the
equation, gives pH=14.0.
However, if the concentration of OH- ions exceeds 1 mol/dm3
(which is very rare), the value of -log [OH-] would be
negative, which, according to the equation, gives a pH of
greater than 14.0.
Therefore, the pH range does not necessarily have a maximum
of 14.0, since there is no limit to the concentration of a
base.
Is This Answer Correct ? | 33 Yes | 2 No |
Post New Answer View All Answers
why we use Dichlorobenzene.nitrobezine.t-butyldi sulhate.for calibration of gc Head space
how we can identify the impurity is coming below loq at transfering site?
when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.
Which is the highly polar and highly non polar column in HPLC?
what is classification of elemental impurities? what is risk assement in elemental impurities?
what is the importance of peak purity in HPLC and how we can calculate through manul(not software)?
if you given one product then which tests you will perform?
why we use glass fiber filters use in some situation?
for heavy metal test lead used in which form pure form or any other form for preparation of lead standard sol
What are modes of quantification in related substances
in OSD forms require to use gas chromatography?
why lactose has less charges when packed in steel containers when compared with packing of lactose in polyamide material?
how require to interprit the method precision data of hptlc?
what is diffrence between specificity and selecivity?
I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?