Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is difference between IR & FTIR ? how we calibarte
both ? I want to know the procedure.

Answer Posted / dr. a. bera, cdl

FTIR interferometer techniques by which it scans 50 times
in a minute, providing better resolution.
It is internally calibrated by He-Ne laser.
Digitally it can be subtracted or can make addition,
But it is costly.

Is This Answer Correct ?    13 Yes 14 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if you get peak in blank then what require to do?

982


how you determine moist.of NaOH sol or NaOH flacks

2228


which batch require to use for analytical method validation?

814


What is diffrence between extractable volume and deliverable volume? Answer pls

4579


In HPLC Calibration, On which basis RSD Limit of noise test is fixed (NMT 33.0 % )

3486


How can I develope method of dissolution by HPLC OR UV

2414


Which are the diffrent grades of api in pharma?

784


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

2225


What is the Formula for coreletion coefficient in plhplc calibration

1841


What is column in chromatography?

2250


what is mean by 40 in the dissolution basket mesh size?

795


what is the procedure for cleaning of lenses of hatr accesory of ftir instrument?

2297


[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?

810


how can give the expiry period and restadardisation of volumetric solution

2602


is it necessary to do HPLC calibration at wavelength 315nm if we are doing analysis at this wavelangth

2180