WHICH PRESSURE IS HIGH EITHER INJECTOR OR DETECTOR IN GAS
CHROMATOGRAPHY
Answer Posted / gl
injector pressure high because injector side using septum
that sample vapours are seprated from the out side world,
thatsway injector pressure high .
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
1)What's the meaning of Absorption,give a example. 2)What's the meaning of Adsorption,give a example. 2)what is the difference between Absorption and Adsorption.
How to calibration of the uv spectroscopy and its test?
From where require to take the RLD sample?
I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?
What is delay volume?
What is the acceptance criteria for moisture balance when calibrated with sodium sulfate
In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?
how require to interprit the method precision data of hptlc?
Why sometime potassium ortho phosphate mix with acetone use for sample preparation for hplc
what is the difference between potentiometric titration and karl fischer titration?
how to develop the icp ms method? Application of icp ms?
My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards
How they found 1mL of K.F reagent is equivalent to 5mg of water and if we change the composition of K.F reagent, is it can neutralize more amount of water?
As per ICH related substances stability trend limit from initial to shelf life
what is the acceptance criteria for enteric coated tablets in 0.1n hcl validation in each parameter?