How to fix the concentration for RS by HPLC

Answer Posted / venkat

Concentration of sample= estimated LOQ concentration (µg/mL) x 1/desired LOQ (%) x 100

Is This Answer Correct ?    45 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is related substance by HPLC impurity limits as per USP?

557


why glutent are detected in the rice cereal baby food product even manufacturer claimed that they are using rice and milk only?we have using ELISA to do the test,and rice supposed not containing any glutent,rite?We already repeat the test so many times and it still detected.just wondering where the glutent came from?

2345


How we performed the force degradation for drug substance, is any specific guideline is available for each parameter(Acidic, basic, oxidation,heat)? what conditions you mentained for above parameters.

1795


What is the main difference between ODS1 and ODS2 Hplc column.

4475


What is the formula to determine the concentration of M of a solution given the % transmittance? Use %T = 43.7 as an example.

2116






In BP2013, Loperamid HCl monograph. Assay by titration with 0.1N sodium hydroxide using hydrocloric acid 0.01N and reading the volume added between the 2 points of inflexion. I have a question that if the diluent solvent is ethanol is certainly consumed a amount of volume of titrant, so this volume must be eliminated on the result calculation or not apart from first point which is subtracted above.

2605


Why Ethanol is Used for Standardization of GC Head space?

3720


if you given one product then which tests you will perform?

321


analytical method validation require to with respect to release specification or shelf life specification?

282


We use Potassium Dichromate solution for the calibration of UV-Visible Spectrophotometer in UV region. My question is to calibrate visible region which solution could be used in photometric accuracy

1319


iam usig ph buffers merk. manually how to prepare ?

1781


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

2976


What is the principle of Thermal conductivity detector and FID?

2259


why sre you used Potassium hydrogen phthalate in standarisation of 1N NaOH and 0.1 N Perchloric Acid?

8914


sop of a uv visible spectrophotometer double beam elico model

5353