Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

whai is primary standard?

Answer Posted / alpesh patel

Compound which is highly stable, easily available and
directly used for standardisation of volumetric solutions
or calibration of various instruments.

Is This Answer Correct ?    8 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why xterra column require to use at higher ph?

927


in hplc chromatogram started from left to right and in uv spectrum started from left to right

959


How doing qbd practically?

984


what is the principle involved in turbidometry and nephelometry ?

4168


what is diffrence between specificity and selecivity?

797


what is the principle of UV Vis spectroscopy, AAS, ICP OES,ICPAES, ICP-MS and FTIR

9258


How require to develop GC method? how to select diluent, GAS, column selection and other chromatographic conditions?

741


How do we get end points and how many end points are possible for citric acid and di-acid not theorotically answer should be given practically.

2590


why require to add enzymes in capsules dissolution only? is it require to tablet also?

685


cefoperozone and sulbactam inj. hplc test method

2700


why lactose has less charges when packed in steel containers when compared with packing of lactose in polyamide material?

2312


How you develop a method in HPLC?

2628


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1608


How to fix the sample conc. in Related substances test by HPLC?

1109


Difference between the quantitative analysis and qualitative analysis?

1192