Electrical Engineering Interview Questions
Questions Answers Views Company eMail

In an ACB shunt trip coil and undervoltage coil operated normally( breaker open and charged). But closing coil not operating untill manually discharge and recharging. Any help.

PPIL,

1275

how to operate and maintenance of 1500 kva diesel generator set

Supertech,

1334

If I have Energy Meter Ratio as 100:5 & Also I have CT Ratio as 50:5 then what will be my multiplying Factor(M.F.)

1535

what is FS cable?? Difference between FS and FRLS??

Multivista Global,

1 8091

What is speed mode?

1241

what maximum range of star & delta in hp or kw ?

Makkah Hilton Towers,

1265

what is the difference between OSR and BUCHHOLZ relay of transformer?

Bhushan Power Steel,

1 7156

if i am in front of transmission line how to know that current direction without any equipment

1243

i am completed diploma in ece,and working in ht and lt lines.so is elligible diploma in ece for get electrical C Licence?plse give ur opinion?

1345

if main CT is of ratio 50/5, and meter CT is -/5 what will be overall multiplying factor of meter.PT is 11000/110 .

BSNL,

1154

how was your last weekend.

HCL,

1329

what is difference between speed mode and torque mode in motor?? explain in simple words please.

Toyota,

1142

If more than rated DC voltage appears across trip coil of the breaker, what will happen? e.g. in 110V DC circuit system, if voltage across battery terminal showing 121 V

1183

How to calculate voltage drop in copper and aluminium cable? I have laid 240Sq.mm Aluminium cable for the length of 600 Mtrs in 1 Mtrs underground. Normal load is 150A. Transformer is 630KVA, 6.KV/433V. But, I am getting only 395 Volts when load. How to calculate voltage drop and what is the permissible voltge drop for this circuit?

1 1751

11kv/433v delta/star distribution transformer primary side full load Ht current is 83.33A in , but input side VCB rating 800A.why?

1203


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

either water sensor or flow meter,how we observe the water level, f any other equipment are in market ?

1410


why we can use 1 to 5V dc

1502


why asa method ZPF method is more accurate than ASA method?

5313


Where burned of electricity,when,who, & why.

1499


For refrigerators the motor current is raised beyond its rating on both conditions when the voltage of the system is more(say 270v) than the rated voltage(220v) as well as when the voltage of system is less(say 160v) than normal voltageof 220v, why explain?

1515






Can anyone provide with a SLD for HT panel installation for a 33KV line and distribution end has three 1.5MV transformers. Is it suitable to use OCB or VCB and also provide me the suitable rating and its connection diagram.

2881


Can anybody please refer the best and simple book for about Protection relays and in detail of all its protection ?

1476


In a voltage-controlled current source A A current booster is never used B The load is always floated C A stiff current source drives the load D The load current equals Isc

1417


pls someone send me sample question papers along with the key.thanks in advance

1875


please send me last 5 year interview questions

1659


how can tell us the AC indoor or outdoor which Tr and formulls

1306


what is the excess air in furnace

1584


What is the physical significant of power factor?

1481


Define piezo-electric effect?

693


what are the standard IR values should be of R-E, Y-E, B-E, R-Y, Y-B, B-R of VCB in closed condition and in open condition for 500KVA & 1000KVA transformers. and what is the acceptable range when tested by 5000V megger.

1840