What is the effect on Power factor and capacitor when your company load is more than 70 % of welding transformer
1819How to protect a Dosing pumps/any sensitive equipment (single phase) from surge protection inside a food factory.
1748How to protect sensitive loads such as Dosing pumps inside a factory from voltage surge/voltage fluctuation.
1809Multi-step core is used in transformer to: A) Increase the output B) Decrease the cost of core material C) Decrease the cost of copper D) Increase the efficiency
1 9197Does outdoor isolator loose connection cause short circuit current in that circuit? if yes then how ??
1700i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.
SCM,
1925I have a reading off 1.5ohms at my mem my main c/b is rated at 40/6 amps in a domestic house and i was told to change it to a b curve c/b is this ok
1671Post New Electrical Engineering Questions
How to calulate Locked rotor amper(LRA) for compressor type motors?
how much allowable resistance that can be difference in motor all coils?
How to calculate earth fault current for 6.6 KV , 50 HZ , 756 Amps , 3000 RPM , 0.8 PF generator
how to design the heater in temperature control unit to heat 50KL of water?
why are distributed windings generally used in alternators?
How do we arrive at selecting reactive capacitance value as 30% of h.p rating of motor?
How we calculate the Multiplying Factor of Kwh meter for 3 phase alternator.
whats the application of voltage regulation? and whats the voltage regulation's device?
We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?
working of diesel generator ?
What are the basic & Majour problems in UPS ?
What are gain margin and phase margin?
how can we understand that where we have to use ac or dc coil for solenoid valve and why?what is the different between coil of ac and dc explain please.
is IS says that neutral should be brought to switch box. and this one is a recomended practice
What is meant by positive and negative feedback?