Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

how u choose thermowell lenght n pnumatic C/v size?

2116

describe flow nozzel principle?

SEWA,

2529

what is controlling card in dcs? how u measure dcs memory?what is bus in dcs?how u know dcs speed n ehternet speed?

2039

what is written on orifice plate?

4 8621

how u calibrate sox nox co2 co in cemps?what is opacity n HPm?tell the standard parameters of cems?

3673

what is piezo electric transducer?its principle?

2 6067

how u calculate ai/di/ao/do capacity in ur dcs?

1 10099

how u calibate pr tx without master tx?

2 5067

how u calibrate pneumatic n motorized c/v?

1976

diff between dead wt calibrator n pressue comparator?

Invensys,

4 10888

I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?

2214

Why DP transmitters are subjected to high static pressure test of 100 bar. Though they will be used for very small pressure range

HPCL,

4 9885

Calibration procedure for water rotameters

HPCL,

2199

How to measure density of oil in your kitchen. i.e indirectly to verify the quality of oil using min. gadgets available in the kitchen/house.

HPCL,

1 4359

give me all the details about the interview and which type of question being asked

Jindal,

2227


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

what is the responsibility of an instrument commissioning supervisor

3165


why is not useing in boiler skin thermocople

5282


What is zero elevation and zero suppression?

2180


what is a vortex flow meter,mass flow meter and electromagnetic flow meter.particular use of this.means in which condition particular meter is used.

2248


A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

2178


Differentiate between ultrasonic flowmeter and radar type flow meter

1223


how to calculate control valve bonnet size?? or how to select its material?

2442


Type of level transmitter commnly used in Procees area are the following. a.________________This type of level transmitter works as follows

2110


Exothermic reaction./ endothermic reaction

2043


How can test or measure the probe and extension cable to identify if the problem at the probe or cable or at the driver it self? (pleast notify the measuring method)

2608


what happen if i increase height of displacer type LT.accuracy or sensitivity are affected.why?

2488


hye SAM acn u send your e mail id, so that i can solve my query through e mail?

2258


steps for installing orifice plate?

1856


what is droop in governer ,type of droop ,how it work

2157


What is the start up procedure of desalter

3686