how calculate column dead volume in hplc ?

3 21367

why 0.005 M sulphuric acid is used to calbrate spectrophotometer and why caffiene is used for calibrating hplc

2 20904

When we calculate Impurity against impurity std.solution and when we calculate impurity against diluted standard with applying RRF?

2 10662

in dissolution why pool sample needed? in which type of drug pool sample need?

2588

what is basc principle of the HPLC,IR,UV AND GC? what is difference between diffusion spectra and transmision spectra in IR?

1 20375

plz tall me that any pharmacopeia and guideline is par meted to use 1.68,4.01,7.00,9.00,12.45 buffer for ph meter calibration

2 3800

what is the difference payment terms in company codelevel and purchase organisation level

1 11857

how much wave length of Soduim vapour lamp used in polarimeter

2 9636

Relation in between KWH & KVAH for Electrical consumption unit & how we can relate if KWH is lower than KVAH

11 138947

IN DISSOLUTION WE ARE USING A LETTER 'Q' WHAT IS MENT BY Q

5 12716

Why we use basket in place of bowl in dissolution apparatus

3 8472

Why 1800 ml of dissolution media used In Carbamazepine ER USP Tablets But other drug only 900 ml Media Used ?

1 4686

Diff between Earthed & Unearthed cable ?

1 4260

what is the balance drift?

2 10576

HELLO FRENDS ,, I M IN THE MIDST OF TROUBLE .. JUST LITTLE HELP ME... SUPPOSE ,, I HAVE A CLOSE VESSELE TANK ( HEXANE MEDIA ) ,, I M USING ROSEMOUNT 2051 DPT FOR LEVEL APPLICATION .. ITS CALIBRATE RANGE IS.. . 0 TO 950 MMH20 ..I DID CALIBRATED DPT WITHOUT REMOVING IMPULSE LINE OF HIGH AND LOW TAPPING.. & WITHOUT DISTURB 3 WAY MANIFOLD..!!! BUT ,,, DURING CALIBRATION I SELECT RANGE BY HART LRV IS 900 MMH20 & URV IS 1300 MMH20 ,, BUT ,TANK LEVEL SOMETIMES 100 % AT 1100 MMH20 , SOMETIMES 1300 MMH20 ..IN THIS CONDITION .. WHOLE LOOP FAILED ,, MAIN THING IS THAT ,, HOW TO CUSTOME RANGE SELECT ?? AND IF I USED RANGE OVER THE ORIGINAL CALIBRATE RANGE ,,,THEN WHAT ERROR WILL BE COME ??? HOW TO ZERO CALIBRATION OF DPT... HOW TO ZERO TRIM BY MANIFOLD ?? AND FOR TANK LEVEL PURPOSE ... WHICH UNIT I CAN USE ??? IS THERE ANY CALCULATION OR CALIBRATION .. IF YEH .. THEN PLZ JUST GIVE ME CALIBRATION STEPS FOR DPT.. THANKS YOURSSSSSSS

1 3764

Post New Torrent Pharma Interview Questions




Un-Answered Questions

How often can a female rat reproduce?

528


What is viewstate error in salesforce?

196


what is a trigger? : Sql dba

568


What are quick parts?

315


What is the difference between snapshot and ami?

127






What is profile in cucumber?

1


List the applications of bluetooth?

524


Is datetime a value type in c#?

487


what are the Default cursor Type and LockEdit type in DAO?

1724


What is 'overseas banking'?

590


State Taylor's theorem and hence obtain Macluarin's expansion in simplified form

657


What is developer responsibilities in UAT (user acceptance testing and Post implementation phase?

1631


How can we run the graph? What is the procedure for that? How can we schedule the graph in unix?

552


How do you compile java?

484


What is spring boot microservices? : Spring Boot

168