What is the power factor you maintain at ur organization?
Answer Posted / gaurav naik
Hey sorry people if i offend you
but here at my place PF is to be maintained above 0.6
but some of you say that penalty is served if PF is below
0.9???
Is it true?
Please reply?
Generally it not possible to maintain PF nearly equal to
unity!!!
0.7-0.9 is fine i guess
Does Electricity rules differ in Evevry state?
We Maintain nearly 0.75 PF but yet no penalty
| Is This Answer Correct ? | 9 Yes | 10 No |
Post New Answer View All Answers
what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero
how can we say that stator magnetic field rotates with synchronous speed?can we derive?
write a c++ code that receives an integer number and display the sum of the number and its revers integer?
How to find ampere on ht side for selection of cable size ???
Usually in the L & T make MCC feeders' power circuit,we have BMR after the MAIN CONTACTOR.,can we interchange their position, keeping the control logic same???
how to calculate differential current when we testing differential relay..suppose we have 1000kw generator,630amp VCB,what value we should put /inject so that relay trip the VCB? PLLZ justify ur comment
how to determine the inrush current of a transformer
hello everybody. what does an abnormal stator winding impedance or dc resistance show? thanx
Can I use star delta connected induction motor for dual supply voltage?
1)how to reduce the value of tan delta of trasformer and CB,bushing,CT&PT,CVT ? 2)how to reduce the resistance of CB contact and its operating time? 3)plz.....send me the project report on conditioning and monitoring of substation equipment on my email id (gusaiyogendra03@gmail.com)
which cable is used for 15 Hp monoblock pump 3phase and service wire Distance is 210 feet please tell me cable size Armaured
If we need4× 50mm sq cable but it's not available so we can pull 4×25mm sq 2cables
Vibromotor 252MV 1/4HP2P..what is mean by 252MV?
at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.
dear sir/madam i want to get some knowledge about RRB EXAMINATION(section engineer) 1- what is minimum cut off 2- wht portion is major portion . 3- can any body provide Sample paper. thanks & regards ashish