what is the purpose of Buffer in any titration?Ex:In
determination of hardness of water we use ammonia
ammoniachloride buffer in titration with EDTA.Why?
Answer Posted / bhagyashree
During reaction between metal and EDTA, H+ ions are formed & decreases the pH of reaction mixture. Hence, a buffer solution of pH 10 is necessary during titration for Ca++ & Mg++ so that it will not allow the decrease of pH.
| Is This Answer Correct ? | 13 Yes | 0 No |
Post New Answer View All Answers
Why acetonitrile and water are used as extraction solvent when analysis melamine? I thought they are miscible and won't be able to separate...
How to decide assay range for non pharmacopeial API analysis by HPLC? Could you give me any reference for same e.g Guidelines or Paper publications?
As per ICH related substances stability trend limit from initial to shelf life
WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?
I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?
Why Ethanol is Used for Standardization of GC Head space?
How do we quantify crystaline and amarpous forms by using (NMR, XRD)spectroscopic techniques? Which any others instruments are useful for this quantification? explain
can we use the same detector in HPLC as well GC and what could be the differences we can find in the final chromato graph in any aspects?
In HPLC (Waters) software Empower1,2 &3 what is the updation for each version
why lactose has less charges when packed in steel containers when compared with packing of lactose in polyamide material?
In HPLC Calibration, On which basis RSD Limit of noise test is fixed (NMT 33.0 % )
What is the Formula for coreletion coefficient in plhplc calibration
In BP2013, Loperamid HCl monograph. Assay by titration with 0.1N sodium hydroxide using hydrocloric acid 0.01N and reading the volume added between the 2 points of inflexion. I have a question that if the diluent solvent is ethanol is certainly consumed a amount of volume of titrant, so this volume must be eliminated on the result calculation or not apart from first point which is subtracted above.
Which type of column should i use to check the purity of high molecular weight protein using HPLC reverse phase column chromatography? Hi everyone. I wanna to check the purity of high molecular weight protein (collagen) with MW of ~130 kDa using a HPLC. I know C18
in dissolution why pool sample needed? in which type of drug pool sample need?