I have got selected for Aurobindo Pharma AR&D, HR person is
asking me to sign in agreement. can I join?
Answer Posted / vishnu
I have also signed a bond for 3 years in aurobindo pharma jadcherla , they appointed 40 members as process engineers and all of us are b.tech graduates.
We did every work said by our superiors , we even worked with daily labourers in sun but now we realized that we were just been used by them for their production ,
Now we are unable to find jobs in engineering department as we have worked here in production , so please don't join aurobindo pharma as process engineer , they don't give minimum respect to you they only want hard working donkey people.
The management here is very weak and the managers in production have only pharma knowledge and they torture us every time .
HR people are also very arrogant .So kindly don't join aurobindo pharma if you want a successful and peaceful life.
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
for inorganic molecules require to do RS, Assay and disso?
In HPLC Calibration, On which basis RSD Limit of noise test is fixed (NMT 33.0 % )
My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards
IS THERE ANY EQUIPMENT TO CHECK AND CALCULATE THE POLARITY OF A LIQUID?
How to know the estimated LOQ concentration in ppm
How we can identify process related and degradation impurity in single method with short period?
How will u perform degradation study in detectors other thann PDA in HPLC Methodology
mode of absorption in alimentary canal?
Explain the relations between number of carbon atoms in alkanes and retention time ?
how you fix the limits of impurities?
what parameters we will consider while developing a HPLC method and how we confirm our HPLC method is valid?
I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?
why we are using hexane in calibration of number of drop per mL
How to set specification of assay, fisdolution and related substances?
Please give idea about method development for cleaning method and how maco level establish