What are Line losses and how can be it minimized/controlled.?
Answer Posted / abc
There typically two types of losses in line T&D.
1. Technical Losses
The technical losses are due to energy dissipated in the conductors, equipment used for transmission line, transformer, subtransmission line and distribution line and magnetic losses in transformers.
Technical losses are normally 22.5%, and directly depend on the network characteristics and the mode of operation.
The major amount of losses in a power system is in primary and secondary distribution lines. While transmission and sub-transmission lines account for only about 30% of the total losses. Therefore the primary and secondary distribution systems must be properly planned to ensure within limits.
The unexpected load increase was reflected in the increase of technical losses above the normal level
Losses are inherent to the distribution of electricity and cannot be eliminated.
There are two Type of Technical Losses.
1. Permanent / Fixed Technical losses
Fixed losses do not vary according to current. These losses take the form of heat and noise and occur as long as a transformer is energized
Between 1/4 and 1/3 of technical losses on distribution networks are fixed losses. Fixed losses on a network can be influenced in the ways set out below
Corona Losses
Leakage Current Losses
Dielectric Losses
Open-circuit Losses
Losses caused by continuous load of measuring elements
Losses caused by continuous load of control elements
2. Variable Technical losses
Variable losses vary with the amount of electricity distributed and are, more precisely, proportional to the square of the current. Consequently, a 1% increase in current leads to an increase in losses of more than 1%.
Between 2/3 and 3/4 of technical (or physical) losses on distribution networks are variable Losses.
By increasing the cross sectional area of lines and cables for a given load, losses will fall. This leads to a direct trade-off between cost of losses and cost of capital expenditure. It has been suggested that optimal average utilization rate on a distribution network that considers the cost of losses in its design could be as low as 30 per cent.
Joule losses in lines in each voltage level
Impedance losses
Losses caused by contact resistance.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Why space heater is required for each verical bus bar chamber? if one space heater is adequate or not for anti condensation?
In HVDC LINE RECTIFIER CONTROL ON CONSTANT CURRENT AND INVERTER CONTROL CONSTANT EXITATION ANGLE CONTROL BUT HOW INVERTER CONTROL CONSTANT CURRENT?
I have 440v power coming to facility,( not being used ) can I buy large generator, (gas) to sell power back to electrical co.
If Neutral Grounding Resistor (GR) failed/shorted. Is it repairable.
WHAT IS DIFFERENCE BETWEEN CAPACITOR AND CAPACITANCE?
how to test YNyn0 vector group in transformer?
what is the principle of operation of CFL ??
in dc suppy frequency is zero why? if dc frequency is zero how to exist dc transients and ac transients
What is the Current equation in series RLC circuits.
why the pf of semiconductor device is improved the electrical devices
how we can come to know that motor winding resistance which showing by DMM is right or wrong???is there any chart or something that we will compare & check???
Who are the manufacturer for Nitrogen based Fire Protectio/explosion prevention for Oil Filled Transformers? India and international both?
Why neutral point is consider as zero potential?
What is the difference between isolators and electrical circuit breakers?
Write masons gain formula.