Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why are using toluene in uv calibraion in resolution
performance

Answer Posted / raveendra reddy.kambam

Toulene gives more maxima at 269 nm and minima at 266 nm, these two are very close to eachother.If any changes in resolution we can easily identify the absorbance difference.

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

1792


Why we use potassium dichromate in uv calibration Exact reason behind it??

1190


1)What's the meaning of Absorption,give a example. 2)What's the meaning of Adsorption,give a example. 2)what is the difference between Absorption and Adsorption.

2832


Why we check moisture,ash & AIA in product

1823


How can the GC or HPLC method is selected to determine the impurity profile in drug product?

7486


How to choose the which salt is suitable for mobilephase

3178


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

2173


Why we select scan range from higer wavelength to lower wavelength in uv visible spectroscopy and ftir spectroscopy ? .

856


What is dose dumping? why require to do?

874


what is classification of elemental impurities? what is risk assement in elemental impurities?

709


what is mean by covalidation

733


Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1745


how the compound separate in coulunm,explain

2446


mode of absorption in alimentary canal?

2341


How to know the estimated LOQ concentration in ppm

1155