Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we use only vanilline , acetanilide,& caffeine For the
Calibration of melting point appartus?

Answer Posted / rupesh

This standards give Linearity
& covers range between 0-300°c .Easily available in market.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A ha tc is actual defination of retention time?

1552


In BP2013, Loperamid HCl monograph. Assay by titration with 0.1N sodium hydroxide using hydrocloric acid 0.01N and reading the volume added between the 2 points of inflexion. I have a question that if the diluent solvent is ethanol is certainly consumed a amount of volume of titrant, so this volume must be eliminated on the result calculation or not apart from first point which is subtracted above.

3067


what is mean by covalidation

731


How we can identify process related and degradation impurity in single method with short period?

758


how much mass should be there in volumetric flask while in preparation of sample for assay? 

2512


If combination product how require to identify which imp is of which api?

789


if your impurity coeluting with each other in that situation how require to set specification? is it acceptable?

900


Which type of column should i use to check the purity of high molecular weight protein using HPLC reverse phase column chromatography? Hi everyone. I wanna to check the purity of high molecular weight protein (collagen) with MW of ~130 kDa using a HPLC. I know C18

1856


in which situation require to use paddle and basket?

670


is it necessary to do HPLC calibration at wavelength 315nm if we are doing analysis at this wavelangth

2105


how to set sample and standard concentration in RS method?

840


what is the structure of DOWEX-50

5452


How to start the dissolution development for unknown tab?

1614


why should we perform dissolution PVT calibration only by UV spectrometer, not by HPLC ?

1643


how to select short coloum and long coloumn for new molecule

2357