Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we get only one peak in assay by hplc but in rs by hplc get more peaks

Answer Posted / k kumar nagendra

In assay by HPLC only the analyte peak is required to calculate againest the standard peak of the sample compuond hence the other impurity peaks are not required so sample in dilute to surtain level to identify the only major single peak hence we get single peak in assay by HPLC.

In some cases both the assay and impurities can be determine with the single method.

Is This Answer Correct ?    11 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how decide the clining method and cleaning method validation require for this perticular products?

729


Is it nessesary all multimedia dissolution require descriminatory?

782


process of Diclofenac sodium,IP.

2189


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

2202


How will u perform degradation study in detectors other thann PDA in HPLC Methodology

2519


for heavy metal test lead used in which form pure form or any other form for preparation of lead standard sol

6047


what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me

2657


can i use hplc detector to uplc and why?

2271


why we use a particular hplc column for a particular compound give reasons?please

2733


What is dose dumping? why require to do?

926


How to calculation of residual solvent methanol (3000 ppm) standard solution, and how many quantity used of test sample

3213


How we performed the force degradation for drug substance, is any specific guideline is available for each parameter(Acidic, basic, oxidation,heat)? what conditions you mentained for above parameters.

2297


What is the diference between residual solvents and organic volatile matter

2011


What is the purpose of octyl silane columns?

4280


What if impurity area in control sample coming more as compared to LOQ level of impurity ?

1586