Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the reason for using the 900ml of dissolution medium

Answer Posted / ganesh

It is not necessary to take 900ml.It varies from dosage form
n its physicochemical property.However according to some
industrial experts,the volume of media is calculated from
saturation solubility of drug.Genrally it should be twice or
thrice times more than saturation solubility of drug
selected for dissolution media.

Is This Answer Correct ?    5 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In the isomers,enantiomers give the only physical properties present such that no chemical properties present.

2210


in dissolution why pool sample needed? in which type of drug pool sample need?

3164


what is biorelivent dissolution media?

793


In performance Check of GC Why Hexadecane Peak is Considered 

3023


why multimedia dissolution require to do?

793


How to calculation of residual solvent methanol (3000 ppm) standard solution, and how many quantity used of test sample

3213


CAN WE DETERMINE THE PEAK PURITY IN GAS CHROMATOGRAPHY ANALYSIS?

1189


if you have given a blank water how you analyse by general analytical techniques?

2016


what is the principle involved in turbidometry and nephelometry ?

4152


how you establish the LOQ?

764


Why six unit used for precision?

1320


Why sodium hydroxide used for maintain pH of phosphate buffer

2384


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3525


if your impurity coeluting with each other in that situation how require to set specification? is it acceptable?

958


how many types of balance calibration test?

2289